5. Disconnect the black and white wires
from the power control switch at the back of
the bracket as shown.
6. Cut and strip the Black, White and Green
wires at the end of the power cord.
7. At the evaporator side (wine room side)
of the unit feed the Black, White and Green
wires from the power cord up through the
hole in the bottom of the bracket until
grommet snaps into place.
8. At the wine room side of the unit, attach
each power cord wire to their respective
chassis wire. i.e. white to white, black to
black and green to green. Use wire nuts
supplied on chassis wires to complete the
installation.
9. At the condenser end of the unit (warm
air side) slide the power control switch to
the opposite position to move power from
the condenser end to the wine room end.
10.Reinstall face plates at both ends of the
unit.