Installing the Condensate Overflow

Condensate generation is a natural by-product of air conditioning systems. The Wine Guardian
cooling coils are designed with the understanding that optimal wine cellar humidity levels are between
55% RH and 60% RH. If the vapor barrier of the wine cellar is poorly constructed or excessive
moisture is in the basement or surrounding areas, then the cooling coil may generate excessive
amounts of moisture. The condensate will appear in the form of water at the cooling coil drain pan
and eventually will travel to the condensate removal system located below the compressor. The Wine
Guardian system features an auxiliary drainport connection located at the condenser end of the system
directly below the plastic face plate
27
RISK OF PERSONAL INJURY OR DAMAGE TO EQUIPMENT
Insert screws into upper pre-drilled hole on both sides of sleeve, continue to
lower set of holes. Ensure screws are flush with wall sleeve. Do not over tighten.
Slide the Wine Guardian Through-the-Wall system through the EasyMount™
sleeve to the desired depth. Please note the Through-the-Wall system must be
slid so that the power cord side is last, not first, to enter the sleeve. Do not
slide the system past the desired flush mounting point.
Seal joint between EasyMount™ sleeve and Wine Guardian system on the
flange side of system with a latex caulk to ensure a tight seal and prevent the
system from horizontal movement. After caulking add the kit supplied self-
adhesive insulate strips tight to the chassis and cover the wall sleeve flanges
to prevent possible sweating.