Relocating the power cord

24
1. Remove Face Plates from both ends of
unit by removing two screws at the base of
each cover. Pull each cover down and away
from unit.
2. At the condenser end (warm air side) of
the unit unscrew the ground lug from
chassis and remove the green wire
connected to the power cord as shown.
3. Re-attach the ground lug onto the chassis
and ensure the other two green ground wires
are secure and attached back onto the
chassis as shown.
4. Use pliers or flat blade screw driver to
push in the tab on the side of the grommet
that holds the power cord within the chassis
bracket. Pull down on power cord to release
from bracket. Power cord can be rotated for
easier access to tab.