Wine Guardian D200 Installation, Operation And Maintenance Manual (96 pages)
Ducted Wine Cellar Cooling Systems
Brand:
Wine Guardian
| Category:
Wine Cooler
| Size: 4.18 MB
Table of Contents
Table of Contents
2
Directory of Terms 缩写语言索引
7
Receiving, Inspecting and Unpacking the
9
Wine Guardian Unit 接收,检查和打开酒卫主机
9
Receiving and Inspecting the Unit 接收,检查
9
Review the Packing Slip to Verify
10
Check the Unit for
10
General Description 概述
11
Standard Specifications 标准规格
12
The Wine Guardian Unit Contains 酒卫主机组包括
12
Accessories and Optional 附件和选项
14
Heating Coils
14
Water Cooled Option
14
Duct Collars and Flexible Ducts
14
Extended Compressor Warranty
14
Low Ambient Option
14
Condensate Pump
15
Humidifier and Humidistat
15
Overview of the Wine Guardian Unit 酒卫主机概述
15
Overview Illustration of the Wine Guardian Unit 酒卫主机插图概述
18
Refrigeration Illustration - Vapor Compression System 制冷插图 - 蒸气压缩系统
18
D025, D050, D050V, WG40 和 WG75 的接线图 Wiring Diagram for D025, D050, D050V, WG40, and WG75
19
D025, D050, D050V, WG40 和 WG75 的接线图(续)Wiring Diagram for D025, D050, D050V, WG40, and WG75 (Cont.)
20
D088, D088V 和 WG100 垂直型号的接线图 Wiring Diagram for D088, Vertical Model D088V, and WG100
21
D088, D088V 和 WG100 垂直型号的接线图(续)Wiring Diagram for D088, Vertical Model D088V, and WG100 (Cont.)
22
D088, D088V 和 WG100 垂直型号的接线图 Wiring Diagram for D088, Vertical Model D088V, and WG100
23
D088, D088V 和 WG100 垂直型号的接线图(续)Wiring Diagram for D088, Vertical Model D088V, and WG100 (Cont.)
24
D200 和 WG175 的接线图 Wiring Diagram for D200 and WG175
25
D200 和 WG175 的接线图(续) Wiring Diagram for D200 and WG175 (Cont.)
26
D025 和 D050 水冷接线图 Wiring Diagram for Water-Cooled D025 and D050
27
D025 和 D050 水冷接线图(续) Wiring Diagram for Water-Cooled D025 and D050 (Cont.)
28
D088 和 D200 水冷接线图 Wiring Diagram for Water-Cooled D088 and D200
29
D088 和 D200 水冷接线图(续)Wiring Diagram for Water-Cooled D088 and D200
30
Wine Guardian Dimensional Data 酒卫外形尺寸
31
Safety 安全
32
Safety Message Conventions 安全信息公约
33
Danger
33
Warning
34
Caution
34
Lockout/Tag out Procedure
35
Safety Considerations 安全注意事项
35
Safety Hazards
36
Electrical Hazards
36
Electrical Shock Hazards
36
Hot Parts Hazards
36
Moving Parts Hazards
36
Equipment Safety Interlocks 设备安全联锁
37
Main Power Switch 主电源开关
37
Installation 安装
40
Pre-Installation Test 安装前的测试
40
Air Flow Illustration 气流插图
41
Planning the Installation 规划安装
43
Addressing Items in the Planning Process 解决规划过程中的问题
43
Performing a Pre-Installation Check 执行安装前检查
43
Locating the Unit
44
Grilles
44
Reducing Noise from the Unit
44
Installing the Unit Outdoors
45
The Wine Guardian Is NOT Designed nor Approved for Direct Outdoor Installation. if It Is Located Outdoors, It MUST be Protected with a Rain-Proofed Enclosure
45
Mounting the Unit 安装主机
46
Floor Mounting
46
Wall Mounting
46
Ceiling Mounting
46
Installing the Condensate Drain Connection
47
Installing the Drain Line 排水管线安装
47
Priming the Drain Trap 引导排水陷阱
48
Wiring the Unit for Power 机组电力线路
48
安装温控器和通信电缆
50
附加的远程接口
51
控制器规格
51
安装远程接口控制器(有线
52
安装酒卫远程遥感器
56
遥感器配对说明-多个传感器(无线
59
标准控制器功能
61
Location of Supply and Return Grilles
70
供应和回笼格栅位置
70
Relocating a Grille on the Wine Guardian 酒卫格栅迁移
70
Installing the Ductwork
71
General Duct Recommendation 一般通风管道的建议
72
Using Ductwork 使用通风管道系统
74
Typical Mounting Arrangements 典型安装的安排
75
Duct Adapter Sizes
76
管道适配器尺寸
76
Dual Outlet Duct Installation 双排气口管道安装
77
Inspection and Start-Up Checklists 检查和启动检查清单
78
Receiving and Inspecting 接收和检查
78
Starting-Up and Operating the Wine Guardian 启动和操作酒卫
79
Turn on the Unit 开动主机
79
Testing the Fan 测试风扇
79
Running the Unit 运行酒卫机器系统
80
Cycling the Unit 机器循环
80
Setting the Thermostat 设置温控器
80
Regulating the Wine Cellar Temperature 酒窖温度调节
81
Changing the Air Flow Direction 改变气流方向
81
Maintenance 维修
82
General 警告
82
Cleaning the Filters 清洁过滤网
83
Cleaning the Condensate Drain System 清洁排水系统
84
Cleaning the Humidifier (Optional)
84
Heating Coil Option 加热线圈选项
84
Low Ambient Option 低温环境选项
85
Maintenance Schedule 维护时间表
86
Monthly 每月
86
Yearly 每年
86
Troubleshooting 疑难解答
87
Typical Start-Up Problems 典型的启动问题
87
Unit Does Not Start-Up 主机不启动机器
88
Power Switch Light Is on and the Thermostat Light Is off
88
Power Switch Light Is on and the Thermostat Light Is on
88
Unit Is Operating and Blows Evaporator Air, but the Supply Air Is Not Colder than the Return Air from the Cellar
89
Problems Controlling Cellar Temperature 酒窖温度控制问题
89
Cellar Temperature too Cold (below 11°C) When Unit Is Running
89
Cellar Temperature Is too Cold (below 11°C) When Unit Is Not Running
90
Problems Controlling Cellar Humidity 酒窖湿度控制问题
90
Humidity too Low or Supply Air Is too Cold, Without Optional Humidifier
90
Humidity too Low, Without Optional Humidifier 湿度太低,无可选加湿机器
91
Humidity too High When Unit Is Running but Not Cooling 主机运行,湿度过高,但不制冷
91
Humidity too High When the Unit Is Not Running 设备未运行,湿度过高
92
Humidity too High When Unit Is Running and Cooling
92
Other Miscellaneous Problems 其他杂项问题
92
Unit Operates but the Power Switch Light Is Not on 机器运行但指示灯不亮
92
Unit Is Leaking Water 机器漏水
93
Unit Is Running Properly, but the Sound of the Unit Is Objectionable 机器运行,但声音不正常
93
High Pressure Switch Has Shut the Unit down 高压开关已将机器关闭
93
Instructions to Reset High Pressure Switch 重设高压开关说明
94
Evaporator Coil Is Freezing 蒸发器线圈冷冻
95
High Pressure Switch Keeps Tripping Even after Checking for Obstructions and Dirty Filters/Coils
95
Unit Cycles on and off more than 8 Times/Hr
95
High Pitched or Loud Rubbing Noise, Clanking or Vibration 有高声摩擦,高噪音,高震动
96
Replacing the Blowers 更换鼓风机
96
Advertisement
Wine Guardian D200 Installation, Operation And Maintenance Manual (52 pages)
Ducted Self-Contained Wine Cellar Cooling Systems
Brand:
Wine Guardian
| Category:
Wine Cooler
| Size: 4.19 MB
Table of Contents
Table of Contents
2
Safety
5
Lockout/Tagout Procedure
6
Safety Warnings
6
Receiving, Inspecting and Unpacking
6
Directory of Terms
7
General Overview
8
Accessories/Options
11
Component Overview
12
Wiring Diagrams
15
Dimensions/Specifications
19
Installation
23
Pre-Installation
23
Pre-Installation Planning
23
Reducing Noise Generation
24
Ductwork
24
Duct Collar and Panel Adjustment
26
Drain Line
27
Wiring to Power
27
Installing the Remote Interface and Communication Cable
29
Additional Remote Interface
30
Controller Specification
30
Mounting the Remote Interface Controller (Wired)
31
Mounting the Remote Interface Controller (Wireless)
32
Installation of the Wine Guardian Remote Sensor
33
Mounting the Remote Sensor (Wired)
33
Mounting the Remote Sensor (Wireless)
35
Remote Sensor Pairing - Multiple Sensors (Wireless)
36
Remote Interface Functions
37
Alarm Codes
44
Start-Up
46
Maintenance
47
Flushing the Water Regulating Valve - Water-Cooled Only
48
Cleaning the Humidifier (Optional)
48
Maintenance Schedule
48
Monthly
48
Yearly
48
Troubleshooting
49
Resetting the High-Pressure Switch
49
Contact and Warranty
51
Contact Information
52
Warranty
52
Wine Guardian D200 Quick Start Installation Manual (24 pages)
Ducted Wine cellar Cooling System
Brand:
Wine Guardian
| Category:
Wine Cooler
| Size: 1.9 MB
Table of Contents
Table of Contents
2
English
3
Deutsch
6
Español
9
Français
12
Italiano
15
Nederlands
18
Advertisement
Advertisement
Related Products
Wine Guardian D200WC
Wine Guardian D050
Wine Guardian D025
Wine Guardian D0200
Wine Guardian DS088
Wine Guardian DS050
Wine Guardian DS025
Wine Guardian DS200
Wine Guardian D050WC
Wine Guardian D088WC
Wine Guardian Categories
Wine Cooler
Humidifier
Kitchen Appliances
Freezer
Air Conditioner
More Wine Guardian Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL