Remote Sensor Pairing – Multiple Sensors (Wireless)
Fig. 1
Fig. 2
Fig. 3
If using multiple remote temperature/humidity sensors in your
application, refer to the figures and the procedure below to change
each remote sensor's device number (Three Remote Sensors
maximum). Each Remote Sensor must have its own device number
and must also be on the same RF channel (Setting 31) as the system
they are being paired with.
1. To change the remote sensor's device number, see the
following instructions:
a.
Use a pin to press the button for about half a second and
release (Fig. 1).
b.
Observe the LED on the side of the remote sensor (Fig. 2&3).
The LED will flash once for a Device #1, twice for a #2, three
times for a #3. At any time, while in this mode press the button
once to change the device number. Once each remote sensor
has its own unique device number simply wait for the LED to
stop flashing and the setting will be saved.
2. To change the remote sensor's RF channel, see the following
instructions:
Note: Check what RF Channel the System is set to using Setting
31 to connect your Remote Sensors more easily.
a. Use a pin to press the red button at the back of the Remote
Sensor for 5 seconds until the LED blinks rapidly then release
the button.
b. The LED will flash several times to portray which RF channel it
is set to and repeat a total of 3 times.
c. To change the RF channel, press the button once to increment
the RF channel. There are 12 possible RF channels. All
Remote Sensors will need to be on the same channel for the
system to detect them. To save the RF channel setting simply
wait for the mode to time out by not pressing the button.
36