Wine Guardian TTW018 Installation, Operation And Maintenance Manual page 34

Through-the-wall wine cellar cooling systems
Table of Contents

Advertisement

Defrost cut-out
temperature
Defrost check
interval
Room
temperature
offset
RH offset
34
Setting 11
Press "Settings" button to advance to
Setting 11.
Press the "Up" or "Down" arrow buttons
to adjust to the desired setpoint. This
setting is adjustable from 35°F to 50°F.
Factory default is 40°F.
Note: This setpoint must be 1°F/°C higher
than setting 10.
Note: If °C is selected and then switched
back to °F the default cut-out will change
to 41°F.
Setting 12
Press "Settings" button to advance to
Setting 12.
Press the "Up" or "Down" arrow buttons
to adjust to the desired setpoint. This
setting is adjustable from 30 min at 0
(zero), 1 hour at 1, and then in 1 hour
increments up to a maximum of 12 hours
at 12.
Setting 13
Press "Settings" button to advance to
Setting 13.
Press the "Up" or "Down" buttons to
adjust to the desired set point. Maximum
setting is +5°F, minimum setting is -5°F.
Factory default is zero (0).
Room temperature offset changes the
actual display reading (temperature only)
by the value of this setting.
Example: Sensor reading = 55°F (13°C)
Setting 13 set to +4
Display reading = 59°F (15°C)
Setting 14
Press "Settings" button to advance to
Setting 14
Press the "Up" or "Down" buttons to
adjust to the desired setpoint. This setting
allows the adjustment of %RH reading by
+/-10%. Factory default is 0%RH.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ttw009Ttw009hWg15Wg25Wg25h

Table of Contents