Universal Robots UR5 Service Manual page 73

With cb3-controller
Hide thumbs Also See for UR5:
Table of Contents

Advertisement

CODE_62A1
High (80 C)
CODE_62A3
Static load too high warning
CODE_62A11
Shut down (85 C)
CODE_62A13
Static load too high
CODE_63
Selftest failed
CODE_68
SPI error
CODE_70
Close to gearbox shear limit
CODE_71
Startup check error
CODE_71A1
Hardware is size1, software is not
CODE_71A2
Hardware is size2, software is not
CODE_71A3
Hardware is size3, software is not
CODE_71A4
Hardware is size4, software is not
CODE_71A5
Invalid hardware size read
CODE_71A6
Motor indication signal not working
CODE_71A7
Phase 1 and phase 2 not working
CODE_71A8
Phase 2 not working
CODE_71A9
Phase 1 not working
CODE_71A10
Invalid motor test result
CODE_71A11
ADC calibration failed
CODE_72
Power Supply Unit failure
CODE_72A1
0 PSUs are active
CODE_72A2
1 PSU active, but we expect 2 (UR10)
CODE_72A3
2 PSUs active, but we expect 1 (UR5)
CODE_73
Brake test failed during selftest, check
brakepin
CODE_74
Joint encoder warning
CODE_74A2
Speed reading is not valid
CODE_74A8
Supply voltage is out of range
CODE_74A16
Temperature is out of range
CODE_74A64
Signal low =Too far from magnetic ring
CODE_74A128
Signal saturation =Too close to magnetic ring
CODE_75
Joint encoder error
CODE_75A1
Invalid decode: Readhead misalignment, ring
damaged or external magnetic field present.
All rights reserved
Acceleration /
deceleration to high.
Mechanical problem
in gear related to
encoder mounting
PSU was not able to
deliver 48V
PSU was not able to
deliver 48V or UR10
flash card in UR5
robot
UR5 flash card in
UR10 robot
73
Servicemanual_UR5_en_rev3.0.2
Reduce acceleration in
user program. Replace
joint if necessary
Check power
connection between
power supply and
Safety Control Board
Check power
connection between
power supply and
Safety Control Board
and check that the flash
card and robot match
Check that the flash
card and robot match

Advertisement

Table of Contents
loading

Table of Contents