CODE_53ATO
, max is 600mA
OL
CODE_55
Safety system error
CODE_55A23
Safety relay error (minus connection)
CODE_55A24
Safety relay error (plus connection)
CODE_55A33
Safety relay error (a relay is stuck)
CODE_55A34
Safety relay error (relays are not on)
CODE_55A50
Voltage present at unpowered robot
CODE_55A51
Voltage will not disappear from robot
CODE_55A52
5V, 3V3 or ADC error (5V too low)
CODE_55A53
5V, 3V3 or ADC error (5V too high)
CODE_55A90
Bootloader error, robot voltage too low or
current too high
CODE_55A91
Bootloader error, robot voltage too high
CODE_55A100
Safety violation
CODE_55A101
Safety Channel Error In Masterboard
CODE_55A102
Safety Channel Error In Screen
CODE_55A103
Safety Channel Error In Euromap67 Interface
CODE_55A109
Received fault message from PC
CODE_55A110
Safety State is changing too often
CODE_55A111
On/Off State is changing too often
CODE_55A112
Robot current sensors readings differ
CODE_55A120
Robot current is too high while emergency
stopped
CODE_55A121
Robot current is too high while safeguard
stopped
CODE_56
Overvoltage shutdown
CODE_57
Brake release failure
CODE_57A1
Joint did not move or motor encoder is not
functioning
CODE_57A2
Large movement detected during brake
release
CODE_57A3
Robot was not able to brake release, see log
for details
CODE_58
Motor encoder not calibrated
CODE_59
Overcurrent shutdown
CODE_62
Joint temperature
All rights reserved
Safety system
malfunction
Voltage exceeded
55V
Overcurrent in joint
72
Servicemanual_UR5_en_rev3.0.2
Check Motherboard,
Masterboard,
Screenboard, Current
distributor( Euromap, if
installed ). Bypass safety
connections to I/O-
interface of
Masterboard
Check Energy Eaters.
Replace Energy Eater
Check for short circuit.
Check program for
singularity issues.
Replace joint if
necessary