4.2.6 Power on value and power failure memory section

If the "Enable Power Failure Memory" is not set, IR-310-RM applies the Power On
Value settings of 10 relay states. Otherwise, the 10 relay states of power failure
memory are used when power is on.
Radio buttons Forward/Stop of power on value are for the forward/stop action in
sequential mode.
Latency (sec) is the delay time to record the 10 relay states after the relay states are
changed. The default is 1800 sec (30 min) and the minimum is 5 sec.
Figure 4-7: Power on value and power failure memory section.

4.2.7 IR Sensor Selection section

There are three selections of IR sensor sources can be set.
(1) On-board IR sensor: The sensor is located in the front panel.
(2) IR Receiver Cable: Use "IR Output" channel. CA-IR-001 needs to be
plugged into the "IR Output" jack (3.5 mm audio jack).
(3) No sensor: Disable the IR remote function.
Figure 4-8: Source of IR sensor.
IR-310-RM, IR Controlled 10-ch High Power Relay Module (Ver. 1.1, Jul/02/2013) 25