a. All Settings:
Download all settings from utility to IR-310-RM.
b. Only IR-Relay-States:
Only download the IR-Relay-States from utility to IR-310-RM.
‧Load Settings from IR-310-RM
When the communication connection is established, utility does not load settings
from IR-310-RM. Users have to click "get" buttons to get setting values in each
section or click this menu item to load all setting values from IR-310-RM.
a. All Settings:
Load all settings from IR-310-RM to utility.
b. Only IR-Relay-States:
Only load the IR-Relay-States from IR-310-RM to utility.
(4) Tool
‧Firmware Update Tool
Launch the firmware update tool. Please refer to 2.6 for firmware update procedure.
""

4.2.3 Relay Output Section

‧ Current 10 relay states indication
This section (figure 3-8) shows the current 10 relay output states after connection
between utility and IR-310-RM is established. Relay ON and OFF means the normally
open (NO) and normally closed (NC) of the relay's contact.
‧ Control 10 relay states for test
Change the ON/OFF state of relays by clicking the circles.
‧Interlocked mode
There are maximum 5 interlocked relay pairs which can be set on IR-310-RM. They
are RL0/RL1, RL2/RL3, RL4/RL5, RL6/RL7, and RL8/RL9. The interlocked relay pairs
are effective when the "Enable Interlocked Mode" checkbox is checked and set.
There are three states for an interlocked relay pairs (e.g. for RL0/RL1):
(1) RL0 is OFF; RL1 is OFF.
(2) RL0 is ON; RL1 is OFF.
(3) RL0 is OFF; RL1 is ON.
Being ON state of both relays is not allowed in a relay pair.
IR-310-RM, IR Controlled 10-ch High Power Relay Module (Ver. 1.1, Jul/02/2013) 23