Sub-Fc 67 (0X43): Set The Independent/Interlocked Mode - ICP DAS USA IR-310-RM User Manual

Ir controlled 10-ch high power relay module
Table of Contents

Advertisement

ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru

5.4.18 Sub-FC 67 (0x43): Set the independent/interlocked mode

‧Request
Byte order
Description
00
Address
01
FC
02
Sub-FC
03
Mode
‧Response
Byte order
Description
00
Address
01
FC
02
Sub-FC
03
Setting result
Note:
1. For the interlocked mode, please refer to Sub-FC 75 and 76 for the settings of the
relay pairs. Maximum 5 relay pairs can be set.
2. For an interlocked relay pair, e.g. RL0 and RL1, three statuses are allowed:
Interlocked Status
1
2
3
IR-310-RM, IR Controlled 10-ch High Power Relay Module (Ver. 1.1, Jul/02/2013) 51
Size
Value
1 Byte
1 ~ 247
1 Byte
0x64
1 Byte
0x43
1 Byte
0=>independent, 1=>interlocked.
Size
Value
1 Byte
1 ~ 247
1 Byte
0x64
1 Byte
0x43
1 Byte
0=>OK, 0xFF=>Error.
Relay 0
ON (NO contact)
OFF (NC contact)
OFF (NC contact)
Relay 1
OFF (NC contact)
ON (NO contact)
OFF (NC contact)

Advertisement