5.4.28 Sub-FC 91 (0x5B) Set Forward/Backward sequential action

‧Request
Byte order
Description
00
Address
01
FC
02
Sub-FC
03
Sequential
action
‧Response
Byte order
Description
00
Address
01
FC
02
Sub-FC
03
Setting
result
Note:
1. This sub-FC is only effective in the sequential mode.
IR-310-RM, IR Controlled 10-ch High Power Relay Module (Ver. 1.1, Jul/02/2013) 61
Size
Value
1 Byte
1 ~ 247
1 Byte
0x64
1 Byte
0x5B
1 Byte
0=>Stop,
1=>forward (turn ON sequentially),
2=>backward (turn OFF sequentially).
Size
Value
1 Byte
1 ~ 247
1 Byte
0x64
1 Byte
0x5B
1 Byte
0x00 => OK, 0xFF=>Error.