5.4.27 Sub-FC 90 (0x5A): Emit IR remote commands for the IR-310-RM
‧Request
Byte order
Description
00
Address
01
FC
02
Sub-FC
03
Modbus Addr. of the
target IR-310-RM
04
IR command number
‧Response
Byte order
Description
00
Address
01
FC
02
Sub-FC
03
Setting result
Note:
1. Please plug in the IR emitter cable and prepare a universal IR learning remote when
using this Sub-FC.
2. Please refer to Sub-FC 69 to set relays' states corresponding to IR command
numbers.
3. Two IR commands with the same IR cmd number but different Modbus Addresses
(Net ID) are different commands which can only control the IR-310pRM with the same
Modbus address.
IR-310-RM, IR Controlled 10-ch High Power Relay Module (Ver. 1.1, Jul/02/2013) 60
Size
Value
1 Byte
0x01~0xF7 (1 ~ 247)
1 Byte
0x64
1 Byte
0x5A
1 Byte
0x01~0xF7 (1 ~ 247)
1 Byte
0 ~ 63 (custom); 192~223 (built-in)
Size
Value
1 Byte
0x01~0xF7 (1 ~ 247)
1 Byte
0x64
1 Byte
0x5A
1 Byte
0=>OK, Others=>Error