4.2.9 Relay States Settings Corresponding to IR Cmds

IR-relay-state can be buffered in each item (#=0~63) of the "IR Cmd No." combobox by
clicking the circles representing the 10 relays RL0 ~ RL9. Click a circle ON means the
relay ON (Normally open). The circle OFF means the relay OFF (Normally closed).
‧ List button
List all IR-relay-states of IR command# 0 ~ 63 buffered in the utility by a sheet.
Figure 4-11: List of IR-relay-states in the utility.
‧ Clear button
Change 10 relay states to OFF state for the item of the IR cmd No combobox.
‧ Clear All button
Change 10 relay states to OFF state for all the items (0 ~ 63) of the IR cmd No
combobox..
‧ Set button
Set the IR-relay-state for the item of the IR cmd No combobox to the connected IR-
310-RM.
‧ Get button
Get the IR-relay-state for the item of the IR cmd No combobox from the connected
IR-310-RM.
IR-310-RM, IR Controlled 10-ch High Power Relay Module (Ver. 1.1, Jul/02/2013) 27
Figure 4-10: Source of IR sensor.