Troubleshooting

Be sure to unplug the power cord from the outlet before looking for the cause of the trouble.
Request repairs at the store where the product was purchased.
Trouble Description
The specified performance
is not obtained
Motor does not turn
There is abnormal noise or
vibration
Dust is exhausted
Dust collecting capability
does not recover even
after servicing the filter unit
Sensor does not function
Solenoid valve does not
function
Static eraser does not
function
Cause/ Inspection
Power specifications do not match
Damaged or clogged filter unit
Defective power connection
Thermal protector has operated
Switch is broken
Motor is burned out
The impeller is not balanced
properly.
Bearing
Damaged or clogged filter unit
Inspect the seal packing
Filter unit installed improperly
Clogged filter unit
Internal component is broken
Internal component is broken
Control circuit is broken
Internal component is broken
33
Troubleshooting
Measures
Match the rated specifications
Replace with a new component
Perform the wiring correctly
Use power voltage that is in a
range of ±10%
Make sure all covers are closed
completely to prevent air leaks
Repair by manufacturer
Repair by manufacturer
Repair by manufacturer
Repair by manufacturer
Replace with a new component
Inspect the seal condition and
replace if necessary
Set it in the proper position after
inspection
Replace with a new component
Repair by manufacturer
Repair by manufacturer
Repair by manufacturer
Repair by manufacturer