Filter Replacement
If the filter has become damaged or if after long use the vacuum force does not recover even after the
dust is removed, use the following procedure to replace the filter. (Filters can be purchased through
the product was purchased.)
Filter unit
The filter unit is located inside of the front cover, so use the following procedure to properly remove
and replace the filter unit.
Remember
Remember
(1) Turn off the switch
(2) Open the front cover
(3) Remove the filter
(4) Install the filter
(5) Close the front cover
WARNING
Make sure the fan has completely stopped rotating before replacing the
filter. In addition, sufficiently monitor the power so that the fan is not
accidentally turned on while the filter is being replaced. If the fan is on, it
will vacuum in things or blow them around, which could cause an
accident.
CAUTION
If the front cover is not attached properly, the vacuum force could drop
or overloading could cause the motor to burnout, so make sure the
cover is attached properly.
Turn off the operation switch and make sure the fan has completely stopped
rotating. Not doing so could result in the collected fine dust being blown
around.
Unlock the thumb lock and take off the front cover.
Remove the internal filter unit.
Install the new filter unit in the original location of the old filter.
Insert the front cover and completely close the thumb lock. If the front cover
is not properly installed, it could cause the vacuum force to drop or overload
the motor and cause it to burn out.
29
Maintenance