4.16.7

Installing RICC Cable (Optical Shelf)

This procedure provides instructions for connecting to the RICC ports on the Optical shelf.
RICC port connectors are located in the station interface area (SIA) at the top front of the
ETSI Optical shelf
Figure 4-56 [p. 4-85]
Note: The RICC cable is only required for HUB configurations.
Cable Part
Number
a
21-332-xxx
a
xxx = length in feet
Step
Task
1
Connect the RJ-45 connector on one end of the RICC cable (21-332-xxx) to connector
CN24, CN25, CN31, or CN32 in the SIA of the Main Optical shelf.
2
Connect the other end of the RICC cable to the appropriate Auxiliary Optical shelf connector
indicated in
Table 4-8 [p.
FNC-7500-0061-200
Issue 1, May 2009
Revision 1, June 2009
(SHU4).Table 4-7 [p. 4-85]
shows the cable connector pinouts.
Table 4-7: LAN Cable Information (ETSI Configuration)
Connector Number
CN24, CN25, CN31, and
CN32 (Main and Auxiliary
Optical shelves)
8
7
RXN
6
5
4
RXP
3
TXN
2
TXP
1
Figure 4-56: Connector Pinouts, RICC Cable
4-86].
Fujitsu and Fujitsu Customer Use Only
ETSI Configuration
lists pertinent information for these cables.