Consecutive same read data validation

By default, transmission occurs after a single successful read.
Compose number of consecutive same reads before transmission
To increase the reliability of the data transmitted, you can set the ScanPlus to validate the
data before transmission—it will only transmit data after a specified number of successful
consecutive reads have given the same result.
Consecutive same read data validation is useful when increased data security is required—
poorly printed codes, codes with variable lengths and without check digits, "fragile" barcode
types.
Increasing the number of consecutive same reads before transmission decreases the
decoding rate.
Example
To make your ScanPlus read the same code successfully 5 times before it
can transmit it:
1. Scan Compose Number of Consecutive Same Reads.
2. Scan 5 then scan End Selection (
SP/XX/RM/10/E/960401
Data decoding security parameters
Single Read Before Transmission (*)
Compose Number of Consecutive Same Reads
Before Transmission (maximum = 10)
cover of this manual).
Number codes or inside back
35