Power-up problems—all models
symptoms
no power-up beeps / green
power-up LED
power-up beeps but no green
LED flash at power-up
green LED flashes a number
of times at power-up
too many green LED flashes
at power-up in spite of correct
interface type selected
continuous green LED at
power-up
error beeps from keyboard
when connecting ScanPlus
3 long beeps at power-up
3 long beeps then 5 short
beeps at power-up
SP/XX/RM/10/E/960401
possible causes
no electrical power or insufficient
electrical power
connection problems
incorrect product components
(ScanPlus model, cables, external
power supply as applicable)
power-up beep / LED deactivated activate power-up beep / LED ( Beeps
energy saver pushbutton model
laser emulation interface selected
number of flashes indicate the
selected interface type
additional flash due to power surge at
power-up
null interface following Reset Factory
Defaults
host system already switched on
EEPROM hardware error
EEPROM integrity error
Troubleshooting
Ð
refer to )
action (
check power supply
check connections ( Connection
diagram for your interface)
check product part numbers, order
form and invoice + Connection
diagram for your interface, Interfaces
/ green indicator LED )
no action if pushbutton is activated—
the power-up beeps and power-up
LED are deactivated in Energy Saver
mode and can not be activated
( Pushbutton models )
no action if your interface is laser
emulation ( Interfaces )
check the number of flashes for
your interface ( Interfaces )
reselect correct interface number
for your system if necessary
( Predefined interface numbers
section for your interface,
Compose interface number ) and
reconfigure
check that additional flash is at
beginning and separate from other
"normal" flashes (if applicable)
scan the predefined interface number
code for your system ( Predefined
interface numbers section for your
interface) or enter the correct
interface number ( Compose interface
number ) and reconfigure
wait a few seconds—the beeps
should stop
contact your UBI representative
contact your UBI representative