Configuration Problems-All Models - UBI ScanPlus 1800 Reference Manual

Intermec scanplus 1800: reference guide
Hide thumbs Also See for ScanPlus 1800:
Table of Contents

Advertisement

Troubleshooting
Configuration problems—all models
symptoms
6 short beeps when reading a
configuration code
no success beeps / green
indicator LED when reading a
configuration code
code mark selection not taken
into account
3 long beeps then 5 short
beeps during configuration
3 long beeps during
configuration
190
possible causes
configuration error:
option not available
interface number not available
optional feature not implemented
commands not read in the correct
order
other setup errors
installation problem
ScanPlus in Configuration Inhibit
After 1 mn mode
you forgot to scan End Selection after
scanning the desired ASCII character
EEPROM integrity error
EEPROM hardware error
Ð
refer to )
action (
check current action—make sure in
particular that you have scanned End
Selection once or twice if required for
the previous parameter
check ScanPlus power supply,
connections ( Connection diagram for
your interface), product components
scan Configuration Enable
( Configuration modes )
re-enter the desired code mark ( Code
mark ) and scan End Selection ( ASCII
character codes )
contact your UBI representative
contact your UBI representative
SP/XX/RM/10/E/960401

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scanplus 1802Scanplus erScanplus xpScanplus pdf

Table of Contents