Symbologies—Standard 2 of 5
Standard 2 of 5 is also referred to as "Straight 2 of 5" and "Industrial 2 of 5".
Activation
Select the desired Standard 2 of 5 format and scan Active to enable.
Not Active (*)
Identicon (6 Start/Stop Bars) (*)
Default values
Standard 2 of 5 format
Check digit
Number of characters
SP/XX/RM/10/E/960401
Symbologies—Standard 2 of 5
Active
Computer Identics (4 Start/Stop Bars)
-
Identicon (6 start/stop Bars)
-
Not Used
-
Minimum Length = 6