UBI ScanPlus 1800 Installation Manual

Intermec scanplus 1800: install guide
Hide thumbs Also See for ScanPlus 1800:

Advertisement

Quick Links

S c a n P l u s
Installation Guide
Edition 1.2
SP/XX/IG/12/E/980228

Advertisement

Table of Contents
loading

Summary of Contents for UBI ScanPlus 1800

  • Page 1 S c a n P l u s Installation Guide Edition 1.2 SP/XX/IG/12/E/980228...
  • Page 2 Notice The ScanPlus products described in this manual comply with CE directives for electromagnetic emission levels and electrical immunity. The information contained in this manual is for informational purposes only and is subject to change without notice. No part of this manual may be copied or reproduced in any manner without the prior written permission of United Barcode Industries.
  • Page 3: Declaration Of Conformity

    Voie No.3, Innopole - BP 187, 31676 Labège Cedex, France Tel: +33 (0)5 61 39 98 58 Fax: +33 (0)5 61 39 20 00 SP/XX/IG/12/E/980228 UBI Scanner Technology Center Immeuble Le Naurouze, Rue Carmin Voie No.3, Innopole - BP 187 31676 Labège Cedex...
  • Page 4 SP/XX/IG/12/E/980228...
  • Page 5: Table Of Contents

    This Installation Guide tells you how to install and set up your ScanPlus to operate successfully in most working situations. The present guide does not cover all the configuration capabilities of your ScanPlus. The full set of configuration options is provided in the ScanPlus Reference Manual . Step by step how to install and set up your ScanPlus 1 Check you have everything you need...
  • Page 6 What you are going to do . . . SP/XX/IG/12/E/980228...
  • Page 7: Check You Have Everything You Need

    Check you have everything you need Checklist of items for your installation the right ScanPlus model all systems this ScanPlus Installation Guide ScanPlus user's leaflet if applicable options external power supply keyboard wedge CMM and associated keyboard/system cables single-output or dual-output RS-232 CMM and associated cables if applicable ScanPlus Reference Manual external power supply 5V or 12V mains power supply adapter—necessary if the host...
  • Page 8 1. Check you have everything you need SP/XX/IG/12/E/980228...
  • Page 9: Switch Off The Host System And Connect Up The Scanplus

    Switch off the host system and connect up the ScanPlus Direct connection or Cable Management Module (CMM) ? Depending on your system configuration, you will either be able to connect your ScanPlus directly to the host system or you will need to use a CMM cable adapter.
  • Page 10: Keyboard Wedge—Scanplus With Y Cable (Pc At And Compatible)

    2. Switch off the host system and connect up the ScanPlus Keyboard wedge—ScanPlus with Y cable (PC AT and compatible) keyboard cable 1. Switch off the host system. 2. Disconnect the keyboard from the host computer. 3. Connect the ScanPlus Y cable between the keyboard and the host computer.
  • Page 11: Keyboard Wedge—Cmm And External Power Supply (If Required)

    2. Switch off the host system and connect up the ScanPlus Keyboard wedge—CMM and external power supply (if required) 1. Switch off the host system. 2. Disconnect the keyboard from the host computer. keyboard cable 3. Use the appropriate keyboard wedge cables to connect the wedge CMM between the keyboard...
  • Page 12: Rs-232—Direct Connection

    2. Switch off the host system and connect up the ScanPlus RS-232—Direct connection 1. Switch off the host system. 2. Connect the ScanPlus to the host computer. RS-232—Single-output CMM and external power supply 1. Switch off the host system. 2. Use the single-output RS-232 CMM to connect the ScanPlus to the host computer.
  • Page 13: Rs-232—Dual-Output Cmm And External Power Supply

    2. Switch off the host system and connect up the ScanPlus RS-232—Dual-output CMM and external power supply 1. Switch off the host system. 2. Use the dual-output RS-232 CMM to connect the ScanPlus between the terminal and the host computer. serial port Õ...
  • Page 14 1. Switch off the host system. 2. Connect the ScanPlus to the cash register. OCIA cash registers 1. Switch off the host system. 2. Connect the ScanPlus to the cash register. Ö port 5x or 9x Ö scanner input port SP/XX/IG/12/E/980228...
  • Page 15 Laser emulation 1. Switch off the host system. 2. Connect the ScanPlus to the host computer. Wand emulation 1. Switch off the host system. 2. Connect the ScanPlus to the host computer. SP/XX/IG/12/E/980228 Ö scanner input port Ö scanner input port...
  • Page 16 2. Switch off the host system and connect up the ScanPlus SP/XX/IG/12/E/980228...
  • Page 17: Switch On The Host System

    Switch on the host system What the beeps and LED flashes mean The ScanPlus should emit two beeps to indicate that the power-up sequence has been completed. The green indicator LED will then indicate the interface type selected for the ScanPlus. green LED indication continuous LED no LED...
  • Page 18 3. Switch on the host system SP/XX/IG/12/E/980228...
  • Page 19: Enter The Interface Number For Your Host System

    Enter the interface number for your host system interface number automatically configures your ScanPlus by setting interface-specific parameters—in particular data transmission parameters—to suit your operating environment Using your ScanPlus You are going to use your ScanPlus to read some of the configuration bar codes provided in this Installation Guide.
  • Page 20: Which Interface Number

    4. Enter the interface number for your host system Which interface number? 1. Look on the next pages to see if there is a predefined interface number for your host system hardware configuration: 2. If you find a number for your hardware configuration, use your ScanPlus to read the corresponding bar code.
  • Page 21: Keyboard Wedge

    4. Enter the interface number for your host system Keyboard wedge IBM PC AT and compatible N° 201 - AZERTY - French N° 205 - QWERTY - Swedish / Finnish N° 207 - QWERTY - Norwegian N° 209 - QWERTY - Spanish SP/XX/IG/12/E/980228 N°...
  • Page 22 4. Enter the interface number for your host system Keyboard wedge IBM 31xx, 32xx, 34xx N° 230 - QWERTY - English N° 232 - AZERTY - international N° 234 - QWERTZ - German N° 2313 - AZERTY - data entry N°...
  • Page 23 4. Enter the interface number for your host system Keyboard wedge DEC VT 220, 320, 420 N° 411 - AZERTY - PC type N° 415 - QWERTY - PC type - Swedish / Finnish DEC VT/PC 510 N° 275 - QWERTY - PC type - Swedish / Finnish N°...
  • Page 24 4. Enter the interface number for your host system Keyboard wedge Apple / Macintosh N° 221 - AZERTY - French Hewlett Packard 700/92 N° 260 - QWERTY - English N° 264 - QWERTZ - German Wyse 60, 65, 99GT, 120 N°...
  • Page 25 4. Enter the interface number for your host system RS-232 N° 100 - Standard RS-232 C (9600, 7, E, 2) N° 101 - RS-232 TTL Level N° 102 - RS-232 PC Term N° 103 - RS-232 Compatible ScanPlus CL Slave Mode N°...
  • Page 26: Laser Emulation

    N° 132 - Laser With Pushbutton Wand emulation N° 130 - Digital Wand Emulation Read N° 131 - Analog Wand Emulation–Intermec Interface if you want to use the following ScanPlus products: ScanPlus SP - P/N 0-320311-11 ScanPlus ER - P/N 0-330311-11 ScanPlus XP - P/N 0-340311-11 wand cable for all three products –...
  • Page 27: Ibm 46Xx Cash Registers

    4. Enter the interface number for your host system IBM 46xx cash registers N° 110 - IBM 46xx cash registers—Port 9x OCIA cash registers N° 120 - OCIA TEC cash registers - First Type N° 122 - OCIA NCR cash registers SP/XX/IG/12/E/980228 N°...
  • Page 28 4. Enter the interface number for your host system 4-10 SP/XX/IG/12/E/980228...
  • Page 29: Set Up The Data Transmission Parameters

    Set up the data transmission parameters data transmission interface-specific communication parameters—in certain cases they need to be modified to optimize the performance of the ScanPlus parameters Scanning the interface number automatically configures your ScanPlus to suit your operating environment by modifying the settings for data transmission to the host system.
  • Page 30 5. Set up the data transmission parameters Keyboard wedge An asterisk (*) indicates the predefined parameter settings for keyboard wedge interface N° 200 (QWERTY - English). Inter-character delay No Delay (*) Postamble Enter (*) Field Exit 20 ms Carriage Return Field Advance No Postamble SP/XX/IG/12/E/980228...
  • Page 31 Keyboard wedge Additional parameters— ScanPlus Reference Manual "code mark" symbology identifiers - not transmitted (*) AIM symbology identifiers - not transmitted (*) special keys interpretation (Code 39) - not active (*) special keys transmission - control characters on (*) end-of-transmission keyboard character status - lower case (*) inter-character delay - 10 - 30 - 40 - 50 ms inter-message delay - none (*) SP/XX/IG/12/E/980228...
  • Page 32 5. Set up the data transmission parameters RS-232 An asterisk (*) indicates the predefined parameter settings for interface N° 100 (Standard RS-232 C). Baud Rate 19200 Data bits Eight Parity Stop bits Two (*) 9600 (*) Seven (*) Even (*) None SP/XX/IG/12/E/980228...
  • Page 33 RS-232 RTS/CTS hardware protocol Not Active (*) Inter-character delay No Delay (*) Postamble Carriage Return + Line Feed (*) Line Feed SP/XX/IG/12/E/980228 5. Set up the data transmission parameters Active 10 ms Carriage Return No Postamble...
  • Page 34 5. Set up the data transmission parameters RS-232 Additional parameters— ScanPlus Reference Manual baud rate - 75 - 150 - 300 - 600 - 1200 - 2400 - 4800 - hardware/software protocols timeout - 1000 ms (*) ENQ (Hex 05) - not used (*) ACK (Hex 06) - not used (*) NAK (Hex 15) - not used (*) XON/XOFF software protocol - not active (*)
  • Page 35 Laser emulation Additional parameters— ScanPlus Reference Manual An asterisk (*) indicates the predefined parameter settings for interface N° 132 (laser with pushbutton). transmitted symbology type - transmission in original code (*) inter-message delay - none (*) logical signal state during transmission - bar = 1, space = 0, margin = 0 (*) logical signal state outside transmission - quiet zone = 1 (*) Wand emulation Additional parameters—...
  • Page 36 5. Set up the data transmission parameters IBM 46xx cash registers Additional parameters— ScanPlus Reference Manual The main predefined parameter settings for IBM 46xx cash registers depend on cash register protocols and can not be modified. An asterisk (*) indicates the predefined transmission delay setting for interface N° 110 / N°...
  • Page 37: Set Up The Symbology Parameters

    Set up the symbology parameters symbology barcode type or "family"—Code 39, UPC and EAN are examples of common symbologies Symbologies and symbology parameters The ScanPlus supports all the most common symbologies. Depending on your ScanPlus model, certain symbologies are already selected by default: ScanPlus SP / ER / XP ScanPlus PDF...
  • Page 38 6. Set up the symbology parameters Symbology default settings When you install your ScanPlus for the first time, Code 39 and UPC/EAN (ScanPlus SP / ER / XP) or PDF417 (ScanPlus PDF) are preselected by default and all the symbology parameters are set to their factory default settings.
  • Page 39 Symbology activation codes and common parameter settings All symbologies are available with all ScanPlus models unless otherwise specified. To optimize the performance of your ScanPlus and to ensure trouble-free scanning, do not select symbologies that you do not need—deactivate the Code 39 and UPC/EAN default symbologies if you do not need to use them.
  • Page 40 6. Set up the symbology parameters Codabar Activation Not Active (*) Start/stop Not Transmitted (*) Barcode length The minimum length possible for Codabar is 3 characters: [start + barcode data + check digit if applicable + stop] For maximum security, we recommend that you use one of the following parameters with all ScanPlus products: Compose 1 or 2 Fixed Lengths (the safest configuration), Compose Minimum Length.
  • Page 41 Codabar Barcode length Compose 1 or 2 Fixed Lengths 1 fixed length: Compose 1 or 2 Fixed Lengths <length>—End Selection—End Selection 2 fixed lengths: Compose 1 or 2 Fixed Lengths <first length>—End Selection <second length>—End Selection—End Selection Compose Minimum Length (default = 6) minimum length: Compose Minimum Length <length>—End Selection Additional parameters—...
  • Page 42 6. Set up the symbology parameters Codablock Activation Codablock is only available with the ScanPlus XP and ScanPlus PDF. Select the desired Codablock format and scan Active to enable. Not Active (*) Codablock F (*) Check digit Not Transmitted (*) Additional parameters—...
  • Page 43 Code 39 Activation Active (*) (ScanPlus SP / ER / XP) Standard 43 Characters (*) Start/stop Not Transmitted (*) Check digit Check Digit Not Used (*) SP/XX/IG/12/E/980228 6. Set up the symbology parameters Not Active (*) (ScanPlus PDF) Full ASCII Transmitted...
  • Page 44 6. Set up the symbology parameters Code 39 Check digit French CIP Check Digit - Checked And Transmitted Italian CPI Check Digit - Checked And Transmitted Barcode length The minimum length possible for Code 39 is 3 characters: [start + barcode data + check digit if applicable + stop] Compose Minimum Length is recommended if you know the minimum length of the codes in your application (especially recommended for the ScanPlus ER).
  • Page 45 Code 39 Additional parameters— ScanPlus Reference Manual accepted start/stop characters - " * " only (*) modulo 43 check digit - checked and transmitted barcode length (number of characters) - any length (*) special keys interpretation (keyboard wedge) - not active (*) SP/XX/IG/12/E/980228 6.
  • Page 46 6. Set up the symbology parameters Code 93 Activation Not Active (*) Additional parameters— ScanPlus Reference Manual barcode length (number of characters) - any length (*) 6-10 Active - minimum length = 6 - minimum length—user-defined SP/XX/IG/12/E/980228...
  • Page 47 Code 128 / EAN 128 New normalization allows decoding of the UCC/EAN standard extension. EAN 128 is auto- discriminating with Code 128 (recognition of the FNC1 start character used). Activation Not Active (*) EAN 128 identifier The ]C1 AIM identifier for EAN 128 is automatically added by default in front of EAN 128 bar codes.
  • Page 48 6. Set up the symbology parameters Code 128 / EAN 128 Additional parameters— ScanPlus Reference Manual FNC1 separator character—EAN-128 norms - GS function character (ASCII 29) (*) barcode length (number of characters) - any length (*) 6-12 - user-defined - minimum length = 6 - minimum length—user-defined SP/XX/IG/12/E/980228...
  • Page 49: Interleaved 2 Of 5

    Interleaved 2 of 5 Activation Not Active (*) Barcode length The minimum length possible for Interleaved 2 of 5 is 2 characters: [barcode data + check digit if applicable] Interleaved 2 of 5 always encodes an even number of characters. To handle codes with an odd number of characters, the ScanPlus will accept a code with the last character printed as 5 narrow bars.
  • Page 50 6. Set up the symbology parameters Interleaved 2 of 5 Barcode length Compose 1 or 2 Fixed Lengths 1 fixed length: Compose 1 or 2 Fixed Lengths <length>—End Selection—End Selection 2 fixed lengths: Compose 1 or 2 Fixed Lengths <first length>—End Selection <second length>—End Selection—End Selection Compose Minimum Length (default = 6) minimum length: Compose Minimum Length...
  • Page 51: Matrix 2 Of

    Matrix 2 of 5 Activation Not Active (*) Barcode length The minimum length possible for Matrix 2 of 5 is 3 characters: For maximum security, we recommend that you use the Compose Minimum Length parameter with all ScanPlus products. Use the special number codes provided on the back cover of this Installation Guide and scan End Selection.
  • Page 52: Msi Code

    6. Set up the symbology parameters MSI Code Activation Not Active (*) Check Digit Check Digit Mod 10—Checked And Transmitted (*) Check Digit Double Mod 10—Checked And Transmitted Additional parameters— ScanPlus Reference Manual barcode length (number of characters) - minimum length = 6 (*) 6-16 Active Check Digit Mod 10—Checked But Not Transmitted...
  • Page 53 6. Set up the symbology parameters PDF417 Activation PDF417 is only available with the ScanPlus PDF. Not Active Active (*) SP/XX/IG/12/E/980228 6-17...
  • Page 54: Plessey Code

    6. Set up the symbology parameters Plessey Code Activation Not Active (*) Check digit Not Transmitted (*) Additional parameters— ScanPlus Reference Manual barcode length (number of characters) - any length (*) 6-18 Active Transmitted - minimum length = 6 - minimum length—user-defined SP/XX/IG/12/E/980228...
  • Page 55: Standard 2 Of

    Standard 2 of 5 Standard 2 of 5 is also referred to as "Straight 2 of 5" and "Industrial 2 of 5". Activation Not Active (*) Barcode length The minimum length possible for Standard 2 of 5 is 3 characters: [barcode data + check digit if applicable] For maximum security, we strongly recommend that you use one of the following parameters with all ScanPlus products:...
  • Page 56 6. Set up the symbology parameters Standard 2 of 5 Barcode length Compose 1 or 2 Fixed Lengths 1 fixed length: Compose 1 or 2 Fixed Lengths <length>—End Selection—End Selection 2 fixed lengths: Compose 1 or 2 Fixed Lengths <first length>—End Selection <second length>—End Selection—End Selection Compose Minimum Length (default = 6) minimum length: Compose Minimum Length...
  • Page 57 UPC/EAN code families (UPC-A, UPC-E, EAN-8, EAN-13) Activation Active—UPC/EAN (*) (ScanPlus SP / ER / XP) UPC-A Transmitted as EAN-13 (*) Add-On Digits—Not Required But Transmitted If Read (*) Add-On 2—Not Active (*) Add-On 5—Not Active (*) SP/XX/IG/12/E/980228 6. Set up the symbology parameters Not Active—UPC/EAN (*) (ScanPlus PDF) UPC-A Transmitted as UPC-A Add-On Digits—Required And Transmitted...
  • Page 58 6. Set up the symbology parameters UPC/EAN code families (UPC-A, UPC-E, EAN-8, EAN-13) Check digit UPC/EAN code format: <leading character> <number system> <data> <check digit> UPC-A Check Digit—Transmitted (*) UPC-E Check Digit—Transmitted (*) EAN-8 Check Digit—Transmitted (*) EAN-13 Check Digit—Transmitted (*) 6-22 UPC-A Check Digit—Not Transmitted UPC-E Check Digit—Not Transmitted...
  • Page 59 UPC/EAN code families (UPC-A, UPC-E, EAN-8, EAN-13) Transmission of number system UPC/EAN code format: <leading character> <number system> <data> <check digit> A regular UPC-A has a transmitted number system equal to 0. To transmit the additional leading character (country code), select the parameter UPC-A Transmitted As EAN-13. UPC-A Number System—Transmitted (*) UPC-E Number System—Transmitted (*) Additional parameters—...
  • Page 60 6. Set up the symbology parameters 6-24 SP/XX/IG/12/E/980228...
  • Page 61: Set Up The Operating Parameters-Activate The Pushbutton

    Set up the operating parameters— Activate the pushbutton operating parameters that affect the way the different ScanPlus models operate—general operating parameters include pushbutton activation, parameters beep and indicator LED settings, operating mode settings, etc. ScanPlus operating parameters Now that you have entered your interface number and set up your data transmission and symbology parameters (if required), you are ready to use your ScanPlus in most working situations.
  • Page 62: Set Up The Operating Parameters—Activate The Pushbutton

    7. Set up the operating parameters—Activate the pushbutton Pushbutton models By default, the pushbutton on ScanPlus pushbutton models is deactivated. To activate the pushbutton, you must select the appropriate pushbutton activation code for your ScanPlus model (standard or energy saver). The ScanPlus does not flash in standby when the pushbutton is activated.
  • Page 63: Pushbutton Activation

    7. Set up the operating parameters—Activate the pushbutton Pushbutton models Pushbutton deactivation By default, the pushbutton on ScanPlus pushbutton models is deactivated. Pushbutton activation Pushbutton operating scenario Other pushbutton operating scenarios are provided in the ScanPlus Reference Manual . The same operating scenario is provided for all pushbutton models— when the pushbutton is pressed, the ScanPlus remains active for a default period of 2 s and goes into standby before the end of this period if there is a good read.
  • Page 64: Pushbutton Models

    7. Set up the operating parameters—Activate the pushbutton Pushbutton models Activation—Standard pushbutton models Only supported by ScanPlus models with part numbers 0-xxxxxx-2x-xx. Do not use this code with ScanPlus models that do not have a pushbutton. Standard Pushbutton Active For Read Duration (2 s)—Standby After Good Read Activation—Standard pushbutton models—Aiming beam Only supported by ScanPlus ER / XP / PDF models with part numbers 0-xxxxxx- 2 x-xx.
  • Page 65 7. Set up the operating parameters—Activate the pushbutton Pushbutton models Additional parameters— ScanPlus Reference Manual standard pushbutton models - active for read duration (2 s) standard pushbutton models—aiming beam - active for read duration (2 s) energy saver pushbutton models - active for read duration (2 s) pushbutton read duration - user-defined (default 2 s, maximum = 65 s) SP/XX/IG/12/E/980228 repeat read duration after good read...
  • Page 66 7. Set up the operating parameters—Activate the pushbutton Additional operating parameters— ScanPlus Reference Manual Additional operating parameters not provided in this Installation Guide. Factory default settings are indicated by an asterisk (*). Configuration modes configuration authorization modes - enable (*) temporary configuration mode - enable transparent configuration mode - enable display data string mode - enable...
  • Page 67 7. Set up the operating parameters—Activate the pushbutton 2D crackle / LED flicker - crackle on (*) Data decoding security parameters predefined security levels - normal security level (*) consecutive same read data validation - single read before transmission (*) time-out between identical consecutive codes - 300 ms (*) time-out between different consecutive codes - no time-out (*) Scan rate parameters—ScanPlus SP...
  • Page 68 7. Set up the operating parameters—Activate the pushbutton SP/XX/IG/12/E/980228...
  • Page 69: A Pin Assignments—Single-Output Rs-232 Cmm

    Pin assignments—Single-output RS-232 CMM Standard DB-25S "DTE" female (P/N 704300) Frame Ground Transmit Data Receive Data Request to Send Clear to Send Signal Ground +5 Volts Standard DB-25S "DCE" female (P/N 704320) Frame Ground Receive Data Transmit Data Clear to Send Request to Send Signal Ground +5 Volts...
  • Page 70 A. Pin assignments—Single-output RS-232 CMM SP/XX/IG/12/E/980228...
  • Page 71: B Jumper Settings—Dual-Output Rs-232 Cmm

    Jumper settings—Dual-output RS-232 CMM Changing the jumper settings 1. Remove the four attachment screws and remove the cover of the CMM. 2. Set the jumpers as required (see the available settings on the next page). Jumper settings are identical for standard and reverse gender dual-output RS-232 CMMs. Make sure the TO HOST and TO TERMINAL labels are correctly positioned when you reassemble the CMM (see RS-232—Dual-output CMM and external power supply in Section 2).
  • Page 72: Jumper Settings

    B. Jumper settings—Dual-output RS-232 CMM Dual-output RS-232 CMM Í terminal DB 25-position male connector < 2 > 3 < 4 > 5 Jumper settings Data transmission settings transmit to host only (default) ScanPlus-host RTS/CTS handshaking settings RTS/CTS handshaking on (default) DUAL RS232 REV A power supply...
  • Page 73: Before You Contact Your Ubi Representative

    If you have a problem . . . This appendix describes things you can try if you have problems with your ScanPlus during power-up, configuration and normal operation. If you can not solve the problem yourself, please contact your UBI representative. Before you contact your UBI representative .
  • Page 74 C. If you have a problem . . . Reading problems checklist correct symbologies selected for the codes you are trying to read symbologies you read are available for your ScanPlus all unnecessary symbologies disabled barcode length compatible with minimum length / fixed length parameter settings of ScanPlus ScanPlus configured for check digit and no check digit present in code...
  • Page 75 Try a general reset of the ScanPlus . . . If you do not find a solution after checking the above points, you can try a general reset of the ScanPlus. Reset Factory Defaults resets all the ScanPlus operating parameters to their factory default settings: null interface (no host system interface driver selected—no transmission), default symbologies and symbology settings,...
  • Page 76 C. If you have a problem . . . 4. Scan the interface number for your system (section 4, Enter the interface number for your host system). 5. Customize the data transmission settings for your host system if required (section 5, Set up the data transmission parameters). 6.
  • Page 77: D Test Codes

    Test codes Codabar 123456 Code 93 CODE-93 EAN 128 ]C1EAN 128 Standard 2 of 5 123456 SP/XX/IG/12/E/980228 Code 39 CODE-39 Code 128 CODE-128 Interleaved 2 of 5 12345678901234 Matrix 2 of 5 012345...
  • Page 78 D. Test codes MSI Code 12345666 EAN-8 12345670 UPC-A 0 1 2 3 4 5 0 0 0 0 Codablock F UBI ScanPlus XP and XP PDF CCD Bar Code Scanners Plessey Code 80001495050 EAN-13 1234567890128 UPC-E 0 1 2 3 4 5 PDF417 UBI ScanPlus XP and XP PDF CCD Bar Code Scanners...
  • Page 79 UBI Inc. Ammendale Technology Park 12240 Indian Creek Court Beltsville MD 20705 Tel: +1 301 210 3000 Fax: +1 301 210 5498 UBI International / UBI France SA Immeuble "Le Newton" 23 avenue de l'Europe 78402 Chatou Cedex FRANCE Tel: +33 (0)1.30.15.25.35 Fax: +33 (0)1.34.80.14.33 UBI GmbH Max-Planck-Strasse 9-13...
  • Page 80: Number Codes

    End Selection SP/XX/IG/12/E/980228 Number codes UBI Part Number: 0-300049-01-12...

Table of Contents