10 Technical data

General technical data
Supply voltage
Weight (case with all product
components)
Case dimensions
Technical data for wireless technology
Wireless technology
Frequency range
Frequencies
Modulation type
Wireless protocol
Output
Specifications for EMC testing for EMC qualified personnel
Directives and manufacturer's declaration – electromagnetic interference
The 743A250 Bionic Pro product is designed for operation in an electromagnetic environment as specified below.
The customer or user of the 743A250 Bionic Pro product must ensure that the device is operated in such an
environment.
Interference measurements
HF emissions according to CIS­
PR11
HF emissions according to CIS­
PR11
Emission of harmonics according to
IEC 61000-3-2
Emission of voltage fluctuations/flick­
er according to IEC 61000-3-3
Directives and manufacturer's declaration – electromagnetic interference immunity
The 743A250 Bionic Pro product is designed for operation in the electromagnetic environment specified below.
The customer or user of the product must ensure that it is operated in such an environment.
INTERFERENCE
IMMUNITY TESTS
Electrostatic
discharge
(ESD)
according
IEC 61000-4-2
Electrical
fast
transi­
ents/bursts according to
IEC 61000-4-4
Surges
according
IEC 61000-4-5
Voltage drops, short inter­
ruptions and fluctuations of
743A250 Bionic Pro
100–240 V AC/50–60 Hz
9 kg
500 x 432 x 118 mm
WLAN
2.4 GHz + 5 GHz
2.412 GHz–2.472 GHz + 5.160 GHz–5.865 GHz
DSSS, CCK, OFDM, BPSK, QPSK, 16QAM, 64QAM
802.11b, 802.11g, 802.11n, 802.11a, 802.11ac
< 20 mW
Compliance
Group 1
Class B
Class A
Complies
IEC 60601 test level
±8 kV contact discharge
to
±15 kV air discharge
± 2 kV for power lines
to
±1 kV voltage
(line-to-line voltage)
0% U
; ½ period at 0, 45,
T
90, 135, 180, 225, 270 and
Electromagnetic environment –
directives
The 743A250 Bionic Pro product
uses HF energy exclusively for its
internal FUNCTIONING. Therefore
its HF emissions are very low and
interference with neighbouring elec­
tronic devices is unlikely.
The 743A250 Bionic Pro product is
intended for use in all facilities
including residential, and those con­
nected directly to the PUBLIC SUP­
PLY NETWORK, which also sup­
plies buildings used as residences.
Compliance level
±8 kV contact discharge
±15 kV air discharge
± 2 kV for power lines
±1 kV voltage
(line-to-line voltage)
0% U
; ½ period at 0, 45,
T
90, 135, 180, 225, 270 and
Technical data
ELECTROMAGNETIC
ENVIRONMENT – direct­
ives
Floors should be wood,
concrete or ceramic tile.
The relative humidity must
be at least 30%.
The quality of the supply
voltage should be equival­
ent to a typical commercial
or hospital supply.
The quality of the supply
voltage should be equival­
ent to a typical commercial
or hospital supply.
The quality of the supply
voltage should be equival­
45