Removing The Dc Power Supply From Cisco Asr 1006 Router - Cisco ASR 1000 Series Installation And Configuration Manual

Cisco systems routers installation and configuration guide
Table of Contents

Advertisement

Removing and Replacing a Cisco ASR 1006 Router Power Supply
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Warning
Statement 1030
Installation of the equipment must comply with local and national electrical codes. Statement 1074
Warning

Removing the DC Power Supply from Cisco ASR 1006 Router

Before you can remove a DC power supply from the Cisco ASR 1006 Router, you must remove power
from the power supply. Follow these steps to remove power and the DC power supply from the chassis.
Make certain that the chassis ground is connected before you begin removing and installing the power
Caution
supply. For the chassis ground stud location.
Before servicing the power supply, switch the circuit breaker Off in your equipment area. As an
Step 1
additional precaution, tape the circuit breaker switch in the Off position.
Slip on the ESD-preventative wrist strap that was included in the accessory kit.
Step 2
Switch the power supply circuit breaker switch to Off (O).
Step 3
Locate the terminal block on the rear of the chassis on the power supply.
Step 4
Figure 8-19
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation and Initial Configuration Guide
8-26
shows the DC power supply terminal block.
Chapter 8
Replacing Cisco ASR 1000 Series Routers Field-Replaceable Units