Removing And Replacing A Dc Power Supply In Cisco Asr 1006 Router - Cisco ASR 1000 Series Installation And Configuration Manual

Cisco systems routers installation and configuration guide
Table of Contents

Advertisement

Chapter 8
Replacing Cisco ASR 1000 Series Routers Field-Replaceable Units
This completes the procedure for installing the AC power supply in the Cisco ASR 1006 Router.

Removing and Replacing a DC Power Supply in Cisco ASR 1006 Router

This section provides information about removing and installing a DC power supply in the Cisco
ASR 1006 Router.
When you install the unit, the ground connection must always be made first and disconnected last.
Warning
Statement 1046
Before performing any of the following procedures, ensure that power is removed from the DC circuit.
Warning
Statement 1003
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Warning
Statement 1030
Figure 8-18
Figure 8-18
8
7
1
2
3
4
5
Warning
Before performing any of the following procedures, ensure that power is removed from the DC circuit.
Statement 1003
OL-13208-03
shows the DC power supply and components for the Cisco ASR 1006 Router.
Cisco ASR 1006 Router DC Power Supply
This unit might have more than one power supply connection. All connections must be removed to de-energize the unit.
6
Fan
DB-25 terminal alarm connector
Tie-wrap tab
DC power supply terminal block and plastic
cover
Earth ground symbol
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation and Initial Configuration Guide
Removing and Replacing a Cisco ASR 1006 Router Power Supply
9
55
-48/-60V
40A
5
4
3
6
DC power supply ground studs
7
DC power supply captive screw
8
DC power supply handle
9
On/Off (|/O) circuit breaker switch
10 Power supply LEDs:
10
OUTPUT INPUT INPUT
FAIL
OK
OK
ALARMS
60V
1A MAX
2
1
8-25

Hide quick links: