Installation Methods - Cisco ASR 1000 Series Installation And Configuration Manual

Cisco systems routers installation and configuration guide
Table of Contents

Advertisement

Chapter 6
Cisco ASR 1002 Router Overview and Installation
The Cisco ASR 1002 Router DC power supply LEDs are defined
Table 6-3
Cisco ASR 1002 Router DC Power Supply LEDs
LED Label
LED
INPUT OK
A bi-color LED indicates
presence of input voltage
FAN OK
A bi-color LED indicates
power supply fan status
OUTPUT FAIL
Power supply activity
The output voltage alarm is declared when the output voltage is below the low end of the minimum or
above the high end of the maximum limits. When the output voltage is above the high end of the
minimum or below the low end of the maximum limits, the Red state will not be activated.
Table 6-4
Table 6-4
Output
12V
3.3V

Installation Methods

Cisco ASR 1002 Router is designed for standalone, two rail 19-inch rack-mount (front rail only), four
rail 19-inch rack-mount (front and rear rail).
Although rack-mounting is the preferred method of installation for the Cisco ASR 1002 Router, you can
mount the chassis on an equipment shelf or tabletop.
OL-13208-03
Color
Green
Amber
Green
Red
Red
shows the DC power supply output voltage alarm range.
DC Power Supply Output Voltage Alarm Threshold Ranges
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation and Initial Configuration Guide
Description
LED illuminates green to signal that the DC power supply
input voltage is greater than 43.5VDC at turn-on and
remains green down to 39VDC.
The LED illuminates amber if the power supply turns off
due to low input voltage (falls below 39VDC) and
indicates that there is still a hazard present (voltage on the
terminal block). The LED remains amber and is active to
around 20V +/-5V. The LED is not illuminated if the input
is below 15V.
The LED illuminates s green when all fans are
operational.
The LED illuminates red when a fan failure is detected.
When the LED is off, it signals that the DC output voltage
are within the normal operating range. Output voltage
between the minimum and maximum limits will not
create an output fail alarm, and output voltages below the
minimum or above the maximum will create an Output
Fail alarm.
Led illuminates red to indicate that the DC output is out
of the specified range.
When you turn the power supply on, the red LED
illuminates for two to three seconds to test LED operation
before going off.
Minimum
10.0-11.2V
2.6 - 3.0V
Installation Methods
inTable
6-3.
Maximum
12.8-13.8V
None
6-9