4.2.3. Download setup data to drive/motor

Press the Download to Drive/Motor button
drive/motor EEPROM memory in the setup table. From now on, at each power-on, the setup data
is copied into the drive/motor RAM memory which is used during runtime. It is also possible to
the setup data on your PC and use it in other applications.
Save
To summarize, you can define or change the setup data in the following ways:
• create a new setup data by going through the motor and drive dialogues
• use setup data previously saved in the PC
• upload setup data from a drive/motor EEPROM memory

4.2.4. Evaluate drive/motor behaviour (optional)

You can use the Data Logger or the Control Panel evaluation tools to quickly measure and
analyze your application behavior. In case of errors like protections triggered, use the Drive
Status control panel to find the cause.

4.3. Changing the drive Axis ID

The axis ID of an IPS110 drive can be set in 2 ways:
Hardware (H/W) – according with the solder joints configuration in the range 1 to 31 or
255 (see 3.3 Jumper and solder joint configuration)
Software – any value between 1 and 255, stored in the setup table
The axis ID is initialized at power on, using the following algorithm:
a) If a valid setup table exists, with the value read from it. This value can be an axis number
1 to 255 or can indicate that axis ID will be set according with DIP switch selection
b) If the setup table is invalid, with the last value set with a valid setup table. This value can
be an axis number 1 to 255 or can indicate that axis ID will be set according with DIP
switch selection
c) If there is no axis ID set by a valid setup table, according with the solder joints
configuration
Remark: If a drive axis ID was previously set by software and its value is not anymore known,
you can find it by selecting in the Communication | Setup dialogue at "Axis ID of drive/motor
connected to PC" the option Autodetected. Apply this solution only if this drive is connected
© Technosoft 2007
to download your setup data in the
41
IPS110 Technical Reference