Manitowoc Welbilt Indigo NXT QuietQube Manual page 91

Remote ice machine
Table of Contents

Advertisement

Indigo NXT QuietQube/CVD: Sequence of Operation
Ice Thaw Cycle
Current Firmware (To prevent Double Slab)
If after a 7 minute harvest cycle and the water curtain
did not activate, Indigo will enter a Water Thaw Cycle:
Cycles
Model
All Indigo
Models
1200lbs or
less
1400lbs or
greater
1200lbs or
18X
less
1400lbs or
greater
All Indigo
Models
1. After completion (Approximately 1-1.75 hours) the ice machine will restart in an initial Start-up.
2. Water curtain activation (open & closed) will not terminate the water thaw cycle. You can bypass by turning the ice machine off and back on –
not by disconnecting power.
NOTE: Water curtain activation (open & closed) will not terminate the water
thaw cycle. You can bypass by turning the ice machine off and back on – not
by disconnecting power.
(Approximately 1-1.75 Hours)
Time
Dump
State
(Seconds)
Valve
Water Fill
0
165
Circulation
240
45
Purge
120
Restart
Water
Harvest
Pump
Valve
Off
On
Off
Off
On
Off
Off
On
Off
On
Off
Off
Restart in an Initial Start up
Water
Compressor
Inlet
Off
On, unit the Hi Water
Level Probe is
Off
satisfied.
Off
Off
Off