Advertisement

Indigo NXT QuietQube/CVD: Sequence of Operation
Auto Restart
1
2
Equalize
Purge
Start
45 Sec
5 Sec
5 Sec
Current Firmware Timers:
Restart from Auto Shut off
•Bin Switch Closes + Bin Sensor not sensing ice
• 6 Minute Lock in on all Freeze Cycles
and 10 minute Delay has Expired
• 35 Minute Max Freeze Cycle
• 7 Minute Max Harvest Cycle
• Water Assist
• Water fill
o Single Evap (6 min max X2 fills)
o Dual Evap (8 min max X2 fills)
35 Minute Max
3
4
Pre-Chill
Freeze
120 Sec.
Ice Thickness
(first cycle)
Probe
30 Sec.
(thereafter)
7
Auto Shut Off
(10 Minute Delay)
5
Harvest
6
Purge
Harvest
45 Sec
Bin Switch
7 Minute Max
Bin Switch
Closes