Manitowoc Welbilt Indigo NXT QuietQube Manual page 19

Remote ice machine
Table of Contents

Advertisement

QuietQube / CVD Installation
Electrical
Ice Machine
Voltage
Install strain relief and proper
Disconnect within 6 feet
Ice Beverage
115/1/60
wiring to ice machine
from Condensing Unit.
Model Head
230/1/50
Section
All Non – IB Model
115/1/60
Head Sections
230/1/50
CVDF0600
208-230/1/60
208-230/3/60
Mount Disconnect Here
208-230/1/50
CVDF0900
208-230/1/60
208-230/3/60
208-230/1/50
Removable Panel
CVDT1200
208-230/1/60
208-230/3/60
CVDF1400
208-230/1/60
208-230/3/60
CVDF1800
208-230/1/60
208-230/3/60
Wiring for the CVD condensing units should be a solid copper
208-230/1/50
CVDF2100
208-230/1/60
conductor.
208-230/3/60
Maximum
Important:
Fuse/Circuit
Due to continuous improvements, this information is
Breaker
for reference only. Please refer to the ice machine
serial number tag to verify electrical data.
15 amp
Ice machine must be grounded
Separate fuse/circuit breaker must be provided for
15 amp
each ice machine
15 amp
Qualified electrician must determine proper wire
size
20 amp
15 amp
20 amp
Maximum allowable voltage variation is ±10% of
25 amp
the rated voltage at ice machine start-up
15 amp
20 amp
Check all green ground screws in the control box
15 amp
40 amp
and verify they are tight before starting the ice
25 amp
machine.
40 amp
50 amp
30 amp
19