Indigo NXT QuietQube/CVD: Sequence of Operation
Ice Thaw Cycle
To prevent Freeze Up:
If after a 7 minute harvest cycle and the water curtain
did not activate, Indigo NXT will enter a Water Thaw Cycle:
Note: Water curtain activation (Open & Closed) will not terminate the water
thaw cycle. You can bypass by turning the ice machine off and back on – not
by disconnecting Power.
(Approximately 1-1.75 Hours)
•
Compressor will shut down.
•
Water pump remain running.
•
Water inlet valve fills the water trough to the "High"
Probe.
•
Circulates approximately 3 min
•
Dump Valve purges water down drain
•
Repeats fill/circulation/purge cycle
X18 times
•
After completion (Approximately 1-1.75 hours) the
ice machine will restart in an initial Start-up.