Manitowoc Welbilt Indigo NXT QuietQube Manual page 133

Remote ice machine
Table of Contents

Advertisement

Indigo NXT Ice Machine Troubleshooting Tips
Service Menu Navigation: Service Data
Service
Data
Real Time
•Time & Temperature
•Inputs
•Outputs
Alert Log
Manual Harvest
Control Board
Replacement
Diagnostics
Control Board:
•Enable Relays
•Self-Check
Contact
Information
USB
iAUCS
:
Data History:
•Current Day
•Current Day -1
•Current Day -2
•Current Day -3
•Current Day -4
•Lifetime
•View
•Clear
•ON
•OFF
Manual Replacement:
•Model Number
•Serial Number
•Cond. Serial Number
•Confirm
USB Replacement:
•Import to ice machine
•Export to USB
Temperature
Inputs:
User Interface:
Sensors:
•Curtain SW 1
•Push button
•Curtain SW 2
•T1
•Display
•HPCO SW
•T2
•Calibrate Screen
•ITP FFT 100HZ
•T3
•ITP FFT 120HZ
•T4
•WLP Low
•T5
•T6
•WLP High
•T7
•Global Locator
•Edit Contact Information
•Upgrade Firmware
•Export Data
•Manually activate iAUCS
Pump
Data
Real Time
:
Time & Temperature
Inputs
•Phase/State
•Phase/State
(Pre-Chill, Freeze,
(Pre-Chill, Freeze,
Harvest, etc...)
Harvest, etc...)
•Timer (00:00:00) Phase/
•Timer (00:00:00) Phase/
State
State
•T-1 Temperature
•Curtain SW:1
•T-2 Temperature
•Curtain SW:2
•T-3 Temperature
•HP.CO Switch
•T-4 Temperature
•ITP FFT 100HZ
•T-5 (Ice Level Kit)
•ITP FFT 120HZ
•T-6 (Not being used)
•Water LVL Low
•T-7 (Not being used)
•Water LVL High
Data History:
•Current Day
Lifetime
•Current Day -1
•Install Date
•Current Day -2
•Control Board Replacement Date
•Current Day -3
•Control Board Manufacture Date
•Current Day -4
•Run Time
•Cycle Count
•Potable Water
•Clean Cycles
•Minimum Freeze
•Length
•Time of day
•T1 Temp (Recorded at 6 minutes into Freeze cycle)
•T2 Temp (Recorded 1 minute before the end of freeze cycle)
•T3 Temp (Recorded at 6 minutes into Freeze cycle)
•T4 Temp (Recorded at 6 minutes into Freeze cycle)
•Maximum Freeze
•Length
•Time of day
•T1 Temp (Recorded at 6 minutes into Freeze cycle)
•T2 Temp (Recorded 1 minute before the end of freeze cycle)
•T3 Temp (Recorded at 6 minutes into Freeze cycle)
•T4 Temp (Recorded at 6 minutes into Freeze cycle)
•Minimum Harvest
•Length
•Time of day
•T1 Temp (Recorded 30 seconds into Harvest cycle)
•T2 Temp (Recorded at 1 minute prior to previous freeze cycle end)
•T3 Temp (Recorded 30 seconds into Harvest cycle)
•T4 Temp (Recorded 30 seconds into Harvest cycle)
•Maximum Harvest
•Length
•Time of day
•T1 Temp (Recorded 30 seconds into Harvest cycle)
•T2 Temp (Recorded at 1 minute prior to previous freeze cycle end)
•T3 Temp (Recorded 30 seconds into Harvest cycle)
•T4 Temp (Recorded 30 seconds into Harvest cycle)
•Run Time
00:00:00, actual run time over the 24 hour period.
•Ice Production
XXXX LBS, ice production over the 24 hour period.
•Cycle Count
XXXX, Cycle Count (Freeze/Harvest) over the 24 hour period.
•Potable Water
XXXX, Potable water (Ice Making) over the 24 hour period.
XXXX, Clean Cycles over the 24 hour period.
•Clean Cycles
Outputs
•Phase/State
(Pre-Chill, Freeze,
Harvest, etc...)
•Timer (00:00:00) Phase/
State
•Water Pump
(on/off)
•Harvest Valve 1
(on/off)
•Harvest Valve 2
(on/off)
•Water Valve
(on/off)
•Dump Valve
(on/off)
•Comp Contactor (on/off)
(XX/XX/XXXX)
(XX/XX/XXXX)
(XX/XX/XXXX)
(Hours)
(XXXXX)
(XXXXX)
(XXXXX)
133
© Welbilt, Inc.

Advertisement

Table of Contents
loading

Related Products for Manitowoc Welbilt Indigo NXT QuietQube

Table of Contents