Indigo NXT QuietQube/CVD: Sequence of Operation
Auto Shut-Off (Bin Probe)
1
2
Equalize
Purge
Start
45 Sec
5 Sec
5 Sec
NOTE: The Control Board doesn't just stop in mid-cycle when the ice level
sensor senses ice. It completes the harvest cycle and then shuts off.
3
4
Pre-Chill
Freeze
30 Sec.
Ice Thickness
(thereafter)
Probe
Auto Shut Off
(10 Minute Delay)
5
Harvest
Purge
Harvest
Bin Switch
45 Sec
7
Auto Shut-Off
•Bin Probe Sensing Ice
•10 Minute Delay for a
Restart
6
Bin Switch Open
for more than
30 seconds