Indigo NXT Ice Machine Troubleshooting
Symptom #2:
QuietQube
®
- Symptom #2 – Ice Machine has a Long Freeze Cycle
QuietQube
Single Evaporator, Single Expansion Valve
Operational Analysis
1
Ice Production
Published 24 hour ice production ____________________
Calculated (actual) ice production ___________________
NOTE:
The ice machine is operating properly if the ice fill pattern is normal and
ice production is within 10% of charted capacity
Installation and Water
All installation and water related problems must be corrected before proceeding with chart.
System
Ice Formation Pattern
Ice formation is extremely
thin on outlet of evaporator
-or-
No ice formation on the top
of the evaporator.
Safety limits
Refer to "Analyzing Safety
Stops on safety limit:
Limits" to eliminate all non-
1 or 2
refrigeration problems.
Freeze Cycle
Discharge Pressure
_______
______
___
1 minute
Middle
End
If discharge pressure is High or Low refer to freeze cycle high or low discharge pressure problem checklist to
into cycle
eliminate problems and/or components not listed on this table before proceeding.
Freeze Cycle
Suction Pressure
If suction pressure is High or Low refer to freeze cycle high or low suction pressure problem checklist to eliminate
_______
______
___
Suction pressure is
High
1 minute
Middle
End
into cycle
Harvest Valve
Audible refrigerant flow
through valve in freeze
cycle
Suction Line
Temperature
Suction line
Attach a temperature probe
temperature at the suction
on the suction line within 6"
shut-off valve is greater
of the shut-off valve outlet.
than
Record the low event at the
10°F (-12.2°C)
end of the freeze cycle.
at the end of the freeze
cycle
Final Analysis
Enter total number of
boxes checked in each
Harvest Valve Leaking
column.
Quiet Qube Refrigeration Operational Analysis Table
Ice Machines Refrigeration Diagnostic Chart
2
3
Ice formation is extremely
Ice formation normal
thin on outlet of evaporator
-or-
-or-
Ice formation is
No ice formation on entire
extremely thin on inlet
evaporator
of evaporator
-or-
No ice formation on
entire evaporator
Stops on safety limit:
Stops on safety limit:
1 or 2
1 or 2
problems and/or components not listed on this table before proceeding.
Suction pressure is
Suction pressure is
Low or Normal
Normal or High
No audible refrigerant flow
No audible refrigerant
through valve in freeze
flow through valve in
cycle
freeze cycle
Suction line
Suction line
temperature at the suction
temperature at the
shut-off valve is greater
suction shut-off
than
valve is
10°F (-12.2°C)
less than
at the end of the freeze
10°F (-12.2°C)
cycle
at the end of the
freeze cycle
Refrigerant
Low on Charge
Overcharge
-or-
-or-
TXV Starving
TXV Flooding
4
Ice formation normal
-or-
No ice formation on entire
evaporator
Stops on safety limit:
1
Suction pressure is
High
No audible refrigerant flow
through valve in freeze cycle
Suction line
temperature at the suction
shut-off valve is
greater than
10°F (-12.2°C)
at the end of the freeze cycle
Compressor
119