Environmental

Temperature, operational
Temperature, non-operational
storage and transportation
Humidity, operational (indoor)
Humidity, non-operational storage
and transportation
Atmospheric pressure, operational
Atmospheric pressure,
non-operational and transportation

Mean Time Before Failure (MTBF)

MURAIPXI-E4SHF
MURAIPXI-E4SF
MURAIPXI-E2MHF
MURAIPXI-E2MF
MURAIPXI-D2MHF
MURAIPXI-D2MF
MURAIPXO-D4LHF
MURAIPXO-D4LF
MURAIPXI-E4JHF
MURAIPXI-E4JF
MURAIPXI-D4JHF
MURAIPXI-D4JF
Mura MPX-4/4
Mura MPX-4/2
Mura MPX-4/0
72 Matrox Display Wall – User Guide
Mura MPX Series: 0 to 40 ºC (32 to 104 ºF)
Mura IPX Series: 0 to 45 ºC (32 to 113 ºF)
C-Series: 5 to 55 ºC (41 to 131 ºF) (near board ambient)
Mura MPX Series and Mura IPX Series: -40 to 65 ºC (-40 to
C-Series: -40 to 70ºC (-40 to 158 ºF)
20 to 80% (non-condensing)
10% to 95% (non-condensing)
650hPa (3,580 meters / 11,745 feet)
to 1013hPa (0 meters / 0 feet)
192hPa (12,000 meters / 39,370 feet)
to 1020hPa (-50 meters / -164 feet)
74.44 years or 652,499 hours
7.21 years or 63,217 hours
75.28 years or 659,887 hours
7.22 years or 63,286 hours
75.28 years or 659,887 hours
7.22 years or 63,286 hours
72.63 years or 636,707 hours
6.56 years or 57,469 hours
76.51 years or 670,700 hours
7.23 years or 63,384 hours
76.51 years or 670,700 hours
7.23 years or 63,384 hours
71.11 years or 622,944 hours
75.41 years or 660,615 hours
90.03 years or 788,631 hours