Regenerative Option Selection; Regenerative Option - Mitsubishi Electric MELSERVO-J5 Series User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-J5 Series:
Table of Contents

Advertisement

3.13

Regenerative option selection

If the generated regenerative power is too large and the regenerative capacity of the built-in regenerative resistor of the servo
amplifier is insufficient, use the regenerative option to improve the regenerative capacity and consume the generated
regenerative power. Set [Pr. PA02.0-1 Regenerative option selection] in accordance with the regenerative resistor in use.
Refer to "Regenerative option" in the following manual for the details of the regenerative options.
MR-J5 User's Manual (Hardware)

Regenerative option

For the regenerative options, select the Mitsubishi Electric-specified regenerative resistor (MR-RB series).
Precautions
• To prevent a fire from occurring, use servo amplifiers with regenerative options in the specified combinations.
Setting method
Servo
Symbol
parameter
PA02.0-1
**REG
3 BASIC FUNCTION
120
3.13 Regenerative option selection
Name
Regenerative option selection
Outline
Select a regenerative option to be used.
Incorrect setting may cause the regenerative option to burn.
If a selected regenerative option is not for use with the servo amplifier, [AL. 037
Parameter error] occurs.
Other regenerative options cannot be used together with the FR-XC-(H).
00: Regenerative option is not used.
• For 100 W servo amplifiers, the regenerative resistor is not used.
• Built-in regenerative resistors are used on servo amplifiers with a capacity of 0.2
kW to 7 kW.
01: FR-XC-(H)
02: MR-RB032
03: MR-RB12
05: MR-RB30
06: MR-RB50 (A cooling fan is required.)
08: MR-RB31
09: MR-RB51 (A cooling fan is required.)
0B: MR-RB3N
0C: MR-RB5N (A cooling fan is required.)
0D: MR-RB14
0E: MR-RB34
1C: MR-RB3Z
1D: MR-RB5Z (A cooling fan is required.)
80: MR-RB1H-4
81: MR-RB3M-4 (A cooling fan is required.)
82: MR-RB3G-4 (A cooling fan is required.)
83: MR-RB5G-4 (A cooling fan is required.)
93: MR-RB3Y-4 (A cooling fan is required.)
94: MR-RB5Y-4 (A cooling fan is required.)
"1C" and "1D" are available on servo amplifiers with firmware version B6 or later.