4-1 Regenerative option

For the regenerative option, always select a regenerative resistor unit or regenerative resistor in the
correct combination for each servo drive unit. Refer to "Appendix 2-2 Selecting the regenerative
resistor" for details on selecting the regenerative option.
The regenerative resistor generates heats, so wire and install the unit while taking care to safety. When
using the regenerative resistor, make sure that flammable matters, such as cables, do not contact the
resistor, and provide a cover on the machine so that dust or oil does not accumulate on the resistor and
ignite.
Regenerative
resistor type
(Japan
Resistor)
Regenerative
resistor unit
type
Regenerative
capacity
Resistance
value
MDS-R-V1-20
MDS-R-V1-40
MDS-R-V1-60
MDS-R-V1-80
MDS-R-V2-2020
MDS-R-V2-4040
MDS-R-V2-6040
MDS-R-V2-6060
MDS-R-V2-8040
MDS-R-V2-8060
MDS-R-V2-8080
Note: Types indicated with a  cannot be used when driving the HF353 motor.
Manufacturer: Japan Resistor
Downloaded from
ManualsNet.com
List of regenerative option correspondence
GZG80
GZG400
GZG200
GZG300
W26
W26
W20
W13
OHMJ
OHMJ
OHMJ
OHMJ
40W
100W
150W
200W
26Ω
26
20
13
search engine
4. Dedicated Options
GZG200
GZG200
W120
W39
GZG400
OHMJ
OHMJ
W8
3 units
3 units
OHMJ
connected
connected
in parallel
in parallel
MR-RB32 MR-RB30 MR-RB50 MR-RB31 MR-RB51 MR-RB65
200W
300W
300W
8
40
13
4 - 2
GZG300
GZG200
GZG300
W39
W20
W20
OHMJ
OHMJ
OHMJ
3 units
3 units
3 units
connected
connected
connected
in parallel
in parallel
in parallel
500W
300W
500W
13
6.7
6.7
GRZG400-2
OHMJ
4 units
connected
in serial
800W
8

Advertisement