G. EMERGENCY PROCEDURE
Follow this procedure only in case of emergency such as a critical error occurred during the
Boot Block Flash BIOS update (when using UBIOS utility program or if you meet one of
the following symptoms at anytime:
1.
No POST code on a power up (when using a POST card).
2.
System stops at POST 41(when using a POST card) and associated beep code is
generated (Refer to Section E.1).
3.
Board does not boot, even after usual hardware and connection verifications.
G.1
H
E
OW TO RUN
MERGENCY
To run an EMERGENCY PROCEDURE, proceed as follows:
1.
Remove battery jumper.
2.
Disable the Power Fail Detection function.
3.
Connected a 1.44MB floppy drive (drive A) to the board, and insert the
EMERGENCY diskette, that you previously created, in it.
4.
Power on the board. (Note that no VGA is present during this procedure.)
5.
Boot block flash update will be completed when the POST code 55 is displayed (when
using a POST card) or the associated beep code sounds (indicated in Section E-5).
6.
After the procedure is successfully completed, power down the board, install your
battery and Power Fail Detection jumpers.
The boot block flash BIOS should be correctly programmed and the system should run
properly.