Installation And Connection Of Auxiliary Equipment And Options; Machines With Timerstart; Limit Switch; Conveyors - Wexiodisk WD-11 Installation And User Manual

Rack conveyor dishwasher
Hide thumbs Also See for WD-11:
Table of Contents

Advertisement

Installation instructions

3.6 Installation and connection of auxiliary equipment and options

The various options normally place no specific requirement on the installation.

3.6.1 Machines with TimerStart

3.6.2 Limit switch

Connection of the limit switch is done on connection X10 in the electrical cabinet.
When connecting, remove the existing clamp on the connection points. See the
machine's wiring diagram The limit switch is designated S11 in the wiring dia-
gram. N.B.! The machine's voltage is 24V.

3.6.3 Conveyors

Installation of in- and outfeed equipment (conveyors, curves) must be performed
in accordance with the wiring diagram's main circuit instructions. This applies to
machines equipped with a motor switch and contactors for this equipment.
Connection of supply voltage to the in- and outfeed equipment is performed in ac-
cordance with the wiring diagram's instructions. N.B.! The machine's voltage is
24V.
When fitting a motor switch and contactors retrospectively, use the components
on the wiring diagram and follow the connection instructions. This affects the
manufacturer's liability. See "SAFETY INSTRUCTIONS".

3.6.4 Emergency stop

Connection of further emergency stops is done to connector X10 in the electrical
cabinet. Replace the existing clamp on the connection points when connecting a
new emergency stop. See the machine's wiring diagram The extra emergency
switch is designated S2 in the wiring diagram. N.B.! The machine's voltage is 24V.
WD-11
Once the machine is in place and has been adjusted horizontally and ver-
tically, the auxiliary equipment can be fitted.
The machine can be equipped with a number of options. Check what your
machine is equipped with, which depends on the model, machine type and
country.
Check the machine's software version, which should be 1.49.6.1 or later.
Check that the reference value for row 108 is set to YES.
20
Rev. 5.0 (202206)

Advertisement

Table of Contents
loading

Table of Contents