Error message
1
Line too high
2
Line too low
3
Character set
4
Unknown BC type
5
Illegal rotation
6
CV font
7
Vector font
8
Measuring label
9
No label found
10
No ribbon
11
COM FRAMING
12
COM PARITY
11.20

10 Error correction

Cause
Line rises up completely or
partly over the upper edge of
label.
Line rises up completely or
partly over the bottom edge of
label.
One res. several characters of
the text is res. are not available
in the selected font.
Selected code is not available.
Selected rotation is not
available.
Selected font is not available.
Selected font is not available.
While measuring no label was
found.
Set label length is too large.
No label available.
Soiled label photocell.
Labels not inserted correctly.
During the print order the
ribbon roll becomes empty
(front printhead).
Defect at the transfer ribbon
photocell (front photocell).
Stop bit error.
Parity error.
Operating Manual
Error correction
Remedy
Move line down (increase Y
value).
Check rotation and font.
Move line up (reduce Y value).
Check rotation and font.
Change text.
Change font.
Check code type.
Check rotation.
Check font.
Check font.
Check label length and if labels
are inserted correctly.
Restart measuring anew.
Insert new label roll.
Check if labels are inserted
correctly.
Clean the label photocell.
Change transfer ribbon.
Check transfer ribbon photocell
(service functions).
Check stop bits.
Check baud rate.
Check cable (printing system
and PC).
Check parity.
Check baud rate.
Check cable (printing system
and PC).