8.12 Service Functions

8.12.1 Photocell Service

Indication of current level at the transmission photocell. No adjustment
possible.
Indication of the lower level at the transmission photocell. No
adjustment possible. The value is determined during the procedure
'measure label'.
Indication of the upper level at the transmission photocell: No
adjustment possible. The value is determined during the procedure
'measure label'.
This value defines the level at the limit between label and liner and
should be approx. 1,0 V above the level. The value is determined
during the 'measure label' procedure and can be readjusted manually,
if necessary.
Setting the contrast of transmission photocell. With particularly strong,
opaque liners, the label recognition can be improved.
Indication of the current level at the reflexion photocell. No adjustment
possible.
Indication of the lower level at the reflexion photocell. No adjustment
possible. The value is determined during the procedure 'measure
label'.
Indication of upper level at the reflexion photocell. No adjustment
possible. The value is determined during the procedure 'measure
label'.
This value defines the level at the limit between mark and liner and
should be approx. 1,0 V above the ninimum level. The value is
determined during the 'measure label' procedure and can be
readjusted manually, if necessary.
Setting the contrast of reflexion photocell. With problematic marks
(color), the label recognition can be improved.
Operating Manual
Function Menu
71