8.12.5 I/O Status

Relevant results are counted and registered in RAM memory. The
protocole get lost after switching off the device.
PrtStrtIntsReal = Real Interrupts
The start input impulses are counted directly at the Interrupt.
PrtStrtIntsDebounced = Debounced
The start input impulses that are longer than the set debounce time
are counted. Only these start impulses can lead to a print. If a start
impulse is too short, no print is released. This is recognized by the fact
that RInt is counted, Dbnc not.
PrtStrtIntsNoPrint = Not Printed
The debounced start input impulses that have not lead to a print are
counted. Causes: no active print order, print order stopped (manually
or because of an error) or the printing system ist still active with the
processing of a print order.
PrtStrtReset = The counters are reset.
PrtStrtTime = Measured length of the last start impulse in ms.
Indication of input signal level
0 = Low
1 = High
Port
Function
1
=
Print start
2
=
Cut
3
=
Counter reset
4
=
External synchronization of label position
5
=
No function
6
=
No function
7
=
No function
8
=
No function
Indication of output signal level
0 = Low
1 = High
Port
Function
9
=
Error
10
=
Print order active
Label available at dispenser photocell – with dispenser
11
=
photocell
12
=
Print end
13
=
Ready
RFID error – only with option RFID
14
=
Scanner: bar code not readable – only with option scanner
15
=
16
=
Ribbon prior warning
Operating Manual
Function Menu
75