General Parameters - Carl Valentin SPE II 106/12 Operating Manual

Table of Contents

Advertisement

SPE II
Photocell
Label synchronization
position
Error length
Synchronization
Label length
Gap length
Label width
Measure label
11.20
Selection of the used photocell.
The selection of one of the following photocell types is possible:
transmission photocell normal and inverse, reflexion photocell normal
and inverse, ultrasonic photocell (option)
(see chapter 11.4, page 111).
Entry of percental label length by that the label end is searched.
Marks onto the label can be skipped.
If no new label can be recognized, indication after how many mm a
message appears in the display.
On: If no new label is recognized, it is not printed. The new data
remains in the memory.
Off: Although no new label is recognized, the next data is printed and
removed from the memory.
8.4.3

General Parameters

Indication of label length in mm.
Indication of distance between two labels in mm
(not for continuous labels).
Indication of label width in mm.
Press the key
to start the measuring process. The printing
system stops automatically after termination of measuring. The
determined values are displayed and saved.
Operating Manual
Function Menu
57