FE: The air purging function is automatically
provided.
Attachment according to IEC 60534-6
(NAMUR rib or attachment to rod-type
yokes) and to rotary actuators
The positioner requires an additional port for
the exhaust air that can be connected over
piping. An adapter available as an accesso-
ry is used for this purpose:
Threaded bush-
ing (M20x1.5)
Note
The adapter uses one of the M20x1.5 con-
nections in the housing which means only
one cable gland can be installed.
Should other valve accessories be used
which vent the actuator (e.g. solenoid valve,
volume booster, quick exhaust valve), this ex-
haust air must also be included in the purg-
ing function. The connection over the adapt-
er at the positioner must be protected with a
check valve (e.g. check valve G ¼, order no.
8502-0597) mounted in the piping. Other-
wise the pressure in the positioner housing
would rise above the ambient pressure and
damage the positioner when the exhausting
components respond suddenly.
EB 8384-4 EN
G ¼
0310-2619
¼ NPT
0310-2550