Manuals and User Guides for Samson 3730-2. We have
10
Samson 3730-2 manuals available for free PDF download: Mounting And Operating Instructions, Operating Instructions Manual, Quick Manual
Samson 3730-2 Mounting And Operating Instructions (176 pages)
Electropneumatic Positioner
Brand:
Samson
| Category:
Valve Positioners
| Size: 17.86 MB
Table of Contents
Table of Contents
3
Safety Instructions and Measures
7
Notes on Possible Severe Personal Injury
11
Notes on Possible Personal Injury
11
Notes on Possible Property Damage
12
Markings on the Device
13
Nameplate
13
Article Code
14
Firmware Versions
16
Design and Principle of Operation
19
Mounting Versions
20
Additional Equipment
20
Configuration Using the TROVIS-VIEW Software
21
Device Overview and Operating Controls
22
Accessories
23
Travel Tables
28
Technical Data
29
Dimensions in MM
35
Fixing Levels According to VDI/VDE 3845 (September 2010)
39
Measures for Preparation
41
Unpacking
41
Transporting
41
Storage
41
Mounting and Start-Up
43
Mounting Position
43
Lever and Pin Position
43
Direct Attachment
46
Type 3277-5 Actuator
46
Type 3277 Actuator
48
Attachment According to IEC 60534-6
50
Attachment According to VDI/VDE 3847-1
52
Attachment According to VDI/VDE 3847-2
56
Version for Single-Acting Actuator
58
Version for Double-Acting Actuator
60
Attachment to Type 3510 Micro-Flow Valve
64
Attachment to Rotary Actuators
64
Heavy-Duty Version
66
Reversing Amplifier for Double-Acting Actuators
70
Reversing Amplifier (1079-1118 or 1079-1119)
70
Attachment of External Position Sensor
72
Mounting the Position Sensor with Direct Attachment
73
Mounting the Position Sensor with Attachment According to IEC 60534-6
75
Mounting the Position Sensor to Type 3510 Micro-Flow Valve
76
Mounting on Rotary Actuators
77
Mounting the Leakage Sensor
78
Retrofitting an Inductive Limit Switch
79
Attaching Positioners with Stainless Steel Housings
80
Air Purging Function for Single-Acting Actuators
80
Pneumatic Connections
83
Connecting the Supply Air
83
Signal Pressure Gauges
84
Supply Pressure
84
Signal Pressure (Output)
85
Electrical Connections
85
Connecting the Electrical Power
88
Switching Amplifier According to en 60947-5-6
89
Operation
91
Serial Interface
93
Operating the Positioner
95
Determining the Fail-Safe Position
96
Adjusting the Volume Restriction Q
96
Adapting the Display Direction
97
Limiting the Signal Pressure
98
Checking the Operating Range of the Positioner
98
Initialize the Positioner
100
MAX - Initialization Based on Maximum Range
102
NOM - Initialization Based on Nominal Range
103
MAN - Initialization Based on a Manually Selected Range
105
Sub - Substitute Calibration
106
Zero Calibration
111
Adjusting Inductive Limit Switch
112
Reset to Default Settings
114
Enabling and Selecting Parameters
115
Operating Modes
116
Automatic and Manual Modes
116
Fail-Safe Position (SAFE)
117
Servicing
119
Firmware Update
119
Preparation for Return Shipment
120
Malfunctions
121
Confirming Error Messages
122
Emergency Action
122
Decommissioning and Removal
123
Decommissioning
123
Removing the Positioner
123
Disposal
123
Appendix
125
After-Sales Service
125
Certificates
125
Code List
126
Error Codes
135
Selecting the Characteristic
143
Advertisement
Samson 3730-2 Mounting And Operating Instructions (140 pages)
Electropneumatic
Brand:
Samson
| Category:
Valve Positioners
| Size: 2.78 MB
Table of Contents
Table of Contents
3
1 Important Safety Instructions
8
2 Article Code
9
3 Design and Principle of Operation
10
Application Type
11
Additional Equipment
12
Configuration Using TROVIS-VIEW Software
13
Technical Data
14
4 Attachment to the Control Valve - Mounting Parts and Accessories
18
Direct Attachment
20
Type 3277-5 Actuator
20
Type 3277 Actuator
22
Attachment According to IEC 60534-6 (NAMUR)
24
Attachment to Type 3510 Micro-Flow Valve
26
Attachment to Rotary Actuators
28
Heavy-Duty Version
30
Reversing Amplifier for Double-Acting Actuators
32
Reversing Amplifier (1079-1118 or 1079-1119)
32
Attaching an External Position Sensor
34
Mounting the Position Sensor with Direct Attachment
34
Mounting the Position Sensor with Attachment According to IEC 60534-6
36
Mounting the Position Sensor to Type 3510 Micro-Flow Valve
37
Mounting the Position Sensor to Rotary Actuators
38
Attaching Positioners with Stainless Steel Housings
39
Air Purging Function for Single-Acting Actuators
39
Mounting Parts and Accessories
40
5 Connections
44
Pneumatic Connections
44
Signal Pressure Gauges
44
Supply Pressure
44
Signal Pressure (Output)
45
Electrical Connections
45
Switching Amplifiers
47
6 Operator Controls and Readings
48
Serial Interface
50
7 Start-Up - Settings
50
Defining the Valve Closed Position
51
Setting the Volume Restriction Q
51
Adapting the Display
52
Limiting the Signal Pressure
52
Checking the Operating Range of the Positioner
53
Initialization
54
MAX - Initialization Based on Maximum Range
55
NOM - Initialization Based on Nominal Range
56
MAN - Initialization Based on a Manually Selected Range
57
Sub Substitute Calibration
59
Zero Calibration
62
Performing Settings for Open/Close Valves
63
Reset to Default Values
65
8 Operation
66
Enabling and Selecting Parameters
66
Operating Modes
67
Automatic and Manual Modes
67
Fail-Safe Position (SAFE)
68
Malfunction/Maintenance Alarm
68
Confirming Error Messages
69
9 Adjusting the Limit Switch
70
Retrofitting an Inductive Limit Switch
72
10 Maintenance
73
11 Servicing Explosion-Protected Devices
73
12 Firmware Update (Serial Interface)
73
13 Maintenance, Calibration and Work on Equipment
74
14 Code List
75
15 Settings in TROVIS-VIEW Software
100
General
100
System Requirements
100
Installing TROVIS-VIEW Software
101
Starting TROVIS-VIEW and Performing Basic Settings
102
Data Transmission
104
Offline Operation (Indirect Data Transmission)
105
Online Operation (Direct Data Transmission)
105
Setting Parameters
106
Initializing the Positioner
108
Status Classification
110
16 Dimensions in MM
112
Fixing Levels According to VDI/VDE 3845 (September 2010)
114
17 Valve Characteristic Selection
115
Test Certificates
117
Samson 3730-2 Operating Instructions Manual (132 pages)
3730 Series, 3731 Series
Brand:
Samson
| Category:
Valve Positioners
| Size: 3.7 MB
Table of Contents
Table of Contents
3
1 Safety Instructions and Measures
7
Notes on Possible Property Damage
9
2 Operation
11
On-Site Operation
11
Operation Using TROVIS-VIEW
11
Differences between Firmware Versions
12
Start-Up
12
Reference Test
14
Diagnostic Functions
15
Application Type
15
Analysis
16
3 Monitoring
19
Status Messages
19
Resetting Status Messages
20
Condensed State
21
Condensed State at the Fault Alarm Output
22
Logging
22
4 Statistical Information
25
Open/Close (On/Off) Valve
27
On/Off Diagnosis
28
Analysis and Monitoring
29
Resetting Single Status Messages
29
Data Logger
31
Permanent Data Logging
31
Triggered Data Logging
32
Travel Histogram X
37
Analysis and Monitoring
38
Resetting Single Status Messages
39
Set Point Deviation Histogram
40
Analysis and Monitoring
41
Resetting Single Status Messages
42
Cycle Counter Histogram
45
Analysis and Monitoring
46
Resetting Single Status Messages
47
Drive Signal Diagram Steady-State
49
Analysis and Monitoring
51
Resetting Single Status Messages
51
Drive Signal Diagram Hysteresis
53
Analysis and Monitoring
55
Resetting Single Status Messages
56
Trend of Travel End Position
59
Analysis and Monitoring
60
Resetting Single Status Messages
61
5 Tests
61
Drive Signal Diagram Steady-State
63
Analysis and Monitoring
65
Resetting Single Status Messages
65
Drive Signal Diagram Hysteresis
67
Analysis and Monitoring
68
Resetting Single Status Messages
69
Static Characteristic
70
Resetting Single Status Messages
71
Partial Stroke Test (PST)
75
Start Triggered by On/Off Valve
80
Start Triggered by the Binary Input
80
Analysis and Monitoring
81
Resetting Single Status Messages
82
Step Response
82
Full Stroke Test (FST)
85
Analysis and Monitoring
88
Resetting Single Status Messages
89
6 Dynamic HART ® Variables
90
7 Leakage Sensor
93
Start-Up of the Leakage Sensor
94
Reference Test
94
Repetition Test
97
Short-Term Monitoring
103
Resetting Single Status Messages
104
Long-Term Monitoring
104
Sound Level Monitoring
105
Resetting Single Status Messages
105
8 Binary Input
106
Types 3730-2/-3 and Type 3731-3
106
Type 3730-4
107
Types 3730-5 and 3731-5
107
9 Appendix
109
Code List
109
PROFIBUS Parameter (Type 3730-4)
115
OUNDATION ™ Fieldbus Parameters (Type 3730-5, Type 3731-5)
118
Error Messages and Recommended Corrective Action
121
Diagnostic Data Points Saved in a Non-Volatile Memory
126
Determining the Ramp Times in Partial Stroke Tests
128
Advertisement
Samson 3730-2 Mounting And Operating Instructions (128 pages)
Series 3730 Electropneumatic Positioner
Brand:
Samson
| Category:
Valve Positioners
| Size: 2.81 MB
Table of Contents
Table of Contents
2
1 Design and Principle of Operation
8
Additional Equipment
9
Technical Data
11
2 Attachment to the Control Valve - Mounting Parts and Accessories
14
Direct Attachment
18
Type 3277-5 Actuator
18
Type 3277 Actuator
20
Attachment According to IEC 60534-6
22
Attachment to Type 3510 Micro-Flow Valve
24
Attachment to Rotary Actuators
26
Reversing Amplifier for Double-Acting Actuators
28
Pressure Gauge Attachment
28
Attaching an External Position Sensor
30
Mounting the Position Sensor with Direct Attachment
30
Mounting the Position Sensor with Attachment According to IEC 60534-6
32
Mounting the Position Sensor to Type 3510 Micro-Flow Valve
33
Mounting the Position Sensor to Rotary Actuators
34
Attaching Positioners with Stainless Steel Housings
36
Air Purging Function for Single-Acting Actuators
36
3 Connections
37
Pneumatic Connections
37
Signal Pressure Gauges
38
Supply Pressure
38
Electrical Connections
39
Switching Amplifiers
41
4 Operation
42
Operator Controls and Display
42
Enabling and Selecting Parameters
44
Operating Modes
45
Automatic and Manual Operating Modes
45
SAFE - Fail-Safe Position
46
5 Start-Up and Settings
46
Determining the Fail-Safe Position
46
Setting Volume Restriction Q
47
Adapting the Display
47
Limiting the Signal Pressure
48
Checking the Operating Range of the Positioner
48
Initialization
49
Initialization Modes
51
Fault/Failure
58
Zero Calibration
59
Reset to Default Values
59
Start-Up Using Local Interface (SSP)
60
Status and Diagnostic Alarms
60
Standard EXPERT Diagnostics
60
Extended EXPERT
61
Classification of Status Alarms and Condensed Status
61
Diagnostics
61
Adjusting the Limit Switch
64
Quick Start-Up Guide
66
Mounting
66
Start-Up
67
Initialization
68
Simplest Method ( MAX )
68
Precise Method ( NOM )
68
Manual Method (MAN)
68
Upgrading Options
69
Retrofitting an Inductive Limit Switch
69
Activating the Optional EXPERT
70
Maintenance
70
Servicing Explosion-Protected Devices
70
Diagnostics
70
Code List
71
Setup with TROVIS-VIEW Software - Parameter List
86
General
86
Starting TROVIS-VIEW and Performing Basic Settings
87
Setting Parameters
90
Parameter List
91
Dimensions in MM
108
Certificates
109
Samson 3730-2 Mounting And Operating Instructions (128 pages)
Electropneumatic Positioner
Brand:
Samson
| Category:
Controller
| Size: 7.67 MB
Table of Contents
Table of Contents
3
1 Important Safety Instructions
8
2 Article Code
9
3 Design and Principle of Operation
10
Additional Equipment
11
Communication
12
Technical Data
13
4 Attachment to the Control Valve - Mounting Parts and Accessories
20
Direct Attachment
22
Type 3277-5 Actuator
22
Type 3277 Actuator
24
Attachment According to IEC 60534-6
26
Attachment According to VDI/VDE 3847
28
Attachment to Type 3510 Micro-Flow Valve
34
Attachment to Rotary Actuators
34
Heavy-Duty Version
36
Reversing Amplifier for Double-Acting Actuators
38
Reversing Amplifier (1079-1118 or 1079-1119)
40
Attachment of External Position Sensor
42
Mounting the Position Sensor with Direct Attachment
43
Mounting the Position Sensor with Attachment According to IEC 60534-6
45
Mounting the Position Sensor to Type 3510 Micro-Flow Valve
46
Mounting on Rotary Actuators
47
Mounting the Leakage Sensor
48
Attaching Positioners with Stainless Steel Housings
49
Air Purging Function for Single-Acting Actuators
49
Required Mounting Parts and Accessories
50
5 Connections
55
Pneumatic Connections
55
Signal Pressure Gauges
55
Supply Pressure
55
Signal Pressure (Output)
56
Electrical Connections
56
Switching Amplifier
59
6 Operating Controls and Readings
60
Serial Interface
62
7 Start-Up and Settings
63
Defining the Fail-Safe Position
63
Adjusting the Volume Restriction Q
64
Adapting the Display Direction
64
Limiting the Signal Pressure
65
Checking the Operating Range of the Positioner
65
Initialization
66
MAX - Initialization Based on Maximum Range
68
NOM - Initialization Based on Nominal Range
69
MAN - Initialization Based on a Manually Selected Range
70
Sub - Substitute Calibration
71
Zero Calibration
74
Reset to Default Settings
75
8 Operation
76
Enabling and Selecting Parameters
76
Operating Modes
76
Automatic and Manual Modes
76
Fail-Safe Position (SAFE)
77
Fault/Malfunction
78
Confirming Error Messages
79
9 Adjusting the Limit Switch
80
Retrofitting an Inductive Limit Switch
81
10 Maintenance
83
11 Servicing Explosion-Protected Devices
83
12 Firmware Update (Serial Interface)
83
13 Maintenance, Calibration and Work on Equipment
84
14 Code List
85
15 Dimensions in MM
103
Fixing Levels According to VDI/VDE 3845 (September 2010)
106
Valve Characteristic Selection
107
Index
126
Samson 3730-2 Mounting And Operating Instructions (120 pages)
Electropneumatic Positioner
Brand:
Samson
| Category:
Valve Positioners
| Size: 1.97 MB
Table of Contents
Table of Contents
2
1 Design and Principle of Operation
8
Additional Equipment
9
Technical Data
10
2 Attachment to the Control Valve - Mounting Parts and Accessories
13
Direct Attachment
16
Type 3277-5 Actuator
16
Type 3277 Actuator
18
Attachment According to IEC 60534-6
20
Attachment to Type 3510 Micro-Flow Valve
22
Attachment to Rotary Actuators
24
Reversing Amplifier for Double-Acting Actuators
26
Attaching an External Position Sensor
28
Mounting the Position Sensor with Direct Attachment
28
Mounting the Position Sensor with Attachment According to IEC 60534-6
30
Mounting the Position Sensor to Type 3510 Micro-Flow Valve
31
Mounting the Position Sensor to Rotary Actuators
32
3 Connections
34
Pneumatic Connections
34
Signal Pressure Gauges
34
Supply Pressure
34
Electrical Connections
35
Switching Amplifiers
37
4 Operation
38
Operator Controls and Display
38
Enabling and Selecting Parameters
40
Operating Modes
41
Automatic and Manual Operating Modes
41
SAFE - Fail-Safe Position
42
5 Start-Up and Settings
42
Determining the Fail-Safe Position
42
Setting the Volume Restriction Q
43
Limiting the Signal Pressure
43
Checking the Operating Range of the Positioner
43
Initialization
45
Initialization Modes
46
Fault/Failure
53
Zero Calibration
54
Reset to Default Values
54
Start-Up Via Local Interface (SSP)
55
6 Status and Diagnostic Alarms
55
Standard EXPERT Diagnostics
55
Extended EXPERT + Diagnostics
56
Classification of the Status Alarms and Condensed Status
56
7 Adjusting the Limit Switch
60
8 Quick Start-Up Guide
61
Mounting
61
Start-Up
62
Initialization
63
Simplest Method ( MAX )
63
Precise Method ( NOM )
63
Manual Method (MAN)
63
9 Retrofitting an Inductive Limit Switch
64
10 Maintenance
65
11 Servicing Explosion-Protected Devices
65
12 Code List
66
13 Setting with TROVIS-VIEW Software - Parameter List
80
General
80
Starting TROVIS-VIEW and Performing Basic Settings
80
Setting the Parameters
84
Parameter List
85
14 Dimensions in MM
103
Test Certificates
104
Samson 3730-2 Mounting And Operating Instructions (88 pages)
Electropneumatic Positioner
Brand:
Samson
| Category:
Valve Positioners
| Size: 1.15 MB
Table of Contents
Table of Contents
2
Design and Principle of Operation
8
Additional Equipment
9
Technical Data
10
Attachment to the Control Valve - Mounting Parts and Accessories
13
Direct Attachment
16
Type 3277-5 Actuator
16
Type 3277 Actuator
18
Attachment According to IEC 60534-6
20
Attachment to Type 3510 Micro-Flow Valve
22
Attachment to Rotary Actuators
24
Reversing Amplifier for Double-Acting Actuators
26
Attaching an External Position Sensor
28
Mounting the Position Sensor with Direct Attachment
28
Mounting the Position Sensor with Attachment According to IEC 60534-6
30
Mounting the Position Sensor to Type 3510 Micro-Flow Valve
31
Mounting the Position Sensor to Rotary Actuators
32
Connections
34
Pneumatic Connections
34
Signal Pressure Gauges
34
Supply Pressure
34
Electrical Connections
36
Switching Amplifiers
37
Operation
38
Operator Controls and Display
38
Enabling and Selecting Parameters
40
Operating Modes
41
Automatic and Manual Operating Modes
41
SAFE - Fail-Safe Position
42
Start-Up and Settings
42
Determining the Fail-Safe Position
42
Setting the Volume Restriction Q
43
Limiting the Signal Pressure
43
Checking the Operating Range of the Positioner
43
Initialization
45
Initialization Modes
46
Start-Up Via Local Interface (SSP)
52
Faults
53
Zero Calibration
53
Reset to Default Values
54
Adjusting the Limit Switch
54
Quick Start-Up Guide
57
Mounting
57
Start-Up
58
Initialization
59
Simplest Method ( MAX )
59
Precise Method ( NOM )
59
Manual Method (MAN)
59
Retrofitting an Inductive Limit Switch
60
Maintenance
61
Servicing Explosion-Protected Devices
61
Code List
62
Dimensions in MM
75
Test Certificates
76
Samson 3730-2 Operating Instructions Manual (40 pages)
EXPERT+ Valve Diagnostics
Brand:
Samson
| Category:
Valve Positioners
| Size: 1.96 MB
Table of Contents
Table of Contents
2
Description
3
General
3
Diagnostic Tests
4
Activating EXPERT
4
Actuator and Valve Specification Data
5
Start the Reference Test
5
Sub Initialization Mode, Double-Acting Actuator and Booster
6
Activation, Analysis and Presentation of Diagnostic Data
7
Printing the Diagnostic/Esd Log
8
Statistical Information AUTO
9
Data Logger
9
Travel Histogram
11
Setpoint Deviation Histogram
12
Cycle Counter Histogram
13
Drive Signal Diagram
15
2.5.1 Steady-State Drive Signal
15
Hysteresis Test (D5)
17
End Position Trend
19
Tests man
21
Test man
21
Drive Signal Diagram Steady-State (D1)
22
Drive Signal Diagram Hysteresis (D2)
23
Static Characteristic (D3)
25
Step Response (D4)
26
Status and Diagnostic Alarms
28
Standard EXPERT Diagnostic Alarms
28
Extended EXPERT + Diagnostic Alarms
28
Logging
29
Classification of the Status Alarms
29
Condensed State
29
Status Modification
30
Resetting Diagnostic Parameters
31
Diagnostic Parameters Saved in Non-Volatile Memory
34
Troubleshooting
35
EXPERT + Without TROVIS-VIEW
38
Samson 3730-2 Quick Manual (2 pages)
Direct attachment to SAMSON Type 3277 Actuator
Brand:
Samson
| Category:
Controller
| Size: 0.11 MB
Samson 3730-2 Quick Manual (2 pages)
Electropneumatic Positioner
Brand:
Samson
| Category:
Valve Positioners
| Size: 0.12 MB
Advertisement
Related Products
Samson 3730 Series
Samson FOUNDATION 3730-5
Samson TROVIS 3730-1
Samson 3730-4
Samson foundation 3787
Samson 3725 series
Samson TROVIS 3730-3
Samson 3767
Samson 3730-6
Samson 3434-1
Samson Categories
Controller
Control Unit
Microphone
Valve Positioners
Speakers
More Samson Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL