Step by Step
DHCP Error 3
DHCP Error 4
Erase Failed
Internal Err. # #
Possible cause:
The server refuses to lease the Wireless Telephone an
IP address.
Possible remedy:
It will keep trying.
Possible cause:
The server offered the Wireless Telephone a lease that
is too short. The minimum lease time is 10 minutes but
Siemens engineers recommend at least one hour mini-
mum lease time. The Wireless Telephone will stop try-
ing.
Possible remedy:
Reconfigure the server and power cycle the Wireless
Telephone.
Possible cause:
Download process failed to erase the memory in the
Wireless Telephone.
Possible remedy:
Operation will retry but may eventually report the
error "int.
error: 0F". Power cycle the phone.
Possible cause:
The Wireless Telephone has detected a fault from
which it cannot recover.
OE = Error while writing the Flash (return Wireless Tele-
phone to factory)
OF = No functional code (contact SpectraLink Technical
Support) .
Possible remedy:
Record the error code so it can be reported. Turn the
Wireless Telephone off then on again. If error persists,
try registering a different Wireless Telephone to this
telephone port. If error still persists, contact Siemens
Technical Support and report the error