Parameters Settings - Leica TS01 User Manual

Table of Contents

Advertisement

5.2
Access
Meas. Parameters
Settings
Field
Option
Pressure:
hPa
mbar
mmHg
inHg
DistanceUnit:
m
US-ft
INT-ft
ft-in1/16
DistanceDec:
3
4

Parameters Settings

1.
Select Setting from the Main Menu.
2.
From the Setting menu, select Parameters Setting.
Key
Description
OK
To confirm the entered values and to continue the process.
Description of fields
Field
Option
Com-
ON
pensator:
OFF
Hz-Correc-
ON
tion:
OFF
Description
Sets the units shown for all pressure fields.
Hecto Pascal.
Millibar.
Millimeter mercury.
Inch mercury.
Sets the units shown for all distance and
coordinate related fields.
Metres [m].
US feet [ft].
International feet [fi].
US feet-inch-1/16 inch [ft].
Sets the number of decimal places shown
for all distance fields. This is for data display
and does not apply to data export or stor-
age.
Displays distance with three decimals.
Displays distance with four decimals.
Description
To turn the compensator on.
To turn the compensator off.
Horizontal corrections are activated. For
normal operation the horizontal correction
should remain active. Each measured hori-
zontal angle will be corrected, depending on
the vertical angle.
Horizontal corrections are deactivated.
Turn the compensator off, if
the instrument is mounted on
unstable ground, such as on a
shaking platform or a ship. Other-
wise, the compensation exceeds
the limit caused by shaking, which
will interrupt the surveying due to
warning messages.