8. Remove the rear vent cover at the back of the cab for access to route cables.
FIGURE 8. Vent Cover
Vent Cover
Removed
9. Route the remaining connectors on the 115-7303-115 cable to the right side of the cab.
10. Feed the four-pin plug through the foam pass-through and out of the cab and towards the back of the sprayer.
11. Feed the seven-pin towards the right-front of the cab.
12. Reinstall the vent cover.
13. Connect the round black seven-pin plug to port number five on the back of the Viper 4.

LEAK TEST

After installation is complete, a leak test is recommended to verify the NCV2s and seals are installed correctly.
1. Complete the Hawkeye® 2 calibration wizard. Refer to the Hawkeye® 2 Calibration and Operations Manual as
necessary.
2. With flushed plumbing and water in the tank, set the system boom pressure to 40 psi.
3. Visually observe for any leaks in any components of the machine.
4. If leaks are observed, turn off the sprayer pump and open a boom section to bleed down the pressure to 0 psi.
5. Verify the NCV2 seals are properly installed and the NCV fly nut is tight.
6. Then, repeat step 2 through 5 as necessary until no leaks are observed.
Cab Preparation and Wiring - Non-Hawkeye® Machines Only: Leak Test