Chapter 3
Hydraulic Motor Installed
FIGURE 14.
Mount the hydraulic motor to the motor mounting bracket using 3/8" x 2-1/2" L bolts (P/N 311-0054-111) and
3.
loosely secure with 3/8" zinc flanged lock nuts.
Install the 3/4" hex shafts.
4.
Note:
Refer to the machine-specific installation guide to determine the section divisions of the planter
and the corresponding 3/4" hex shaft.
Secure the hex shafts with existing shaft collars, supplied hex collars (P/N 107-0172-082), and/or cotter
5.
pins on the opposite side of the existing bearing or sprocket that is not next to an OmniRow hydraulic motor.
Insert the supplied cotter pin (P/N 312-0000-395) in the hex coupler to secure the installed shafts.
6.
Secure any wires within close proximity of the installed hydraulic motor to prevent interference with the
7.
operation of the row unit.
Note:
Do not secure the wires between the motor and the row unit mounting bracket, as this makes it
difficult to access the wires if maintenance is required.
Verify the motor, shaft, and bearings are aligned.
8.
Tighten the nuts to secure the installed motor and mounting bracket to the row unit.
9.
Repeat the steps above to install hydraulic motors on the remaining right mounting planter row units
10.

Install the Pressure Gauge Test Kit

The OmniRow hydraulic motors are rated up to 200 psi of back pressure. To protect the motors, reduce
pressure to the PWM valves, and improve performance, pressure test ports will need to be installed in the
hydraulic system to allow the hydraulic system performance to be tested.
Note:
If the implement has motors controlling multiple rows, choose a section with the most row units
being controlled by a single motor to perform the test.