Catch Test

Note:
The priming procedure should be performed before performing the catch
test procedure.
1. Press the Next key to select the 'Start Calibration' option and press the Enter
key.
2. Press the Start key.
3. Continue dispensing product until a sufficient weight is in the weight box or the
weight box is full.
4. Press the End key to complete the calibration.
Note:
Press the Stop key during the calibration process to pause the calibration
and stop the metering rollers if necessary. While paused, press Start key
to resume the catch test. It is recommended to run the catch test without
pausing the calibration to get the most accurate results.
Press the Cancel key to stop the calibration process and return to the
calibration screen without entering a cal weight.
5. Weigh the product dispensed (minus the weight box). The Metered Weight
Page will display automatically at the end of the catch test procedure.
6. Use the Left and Right keys to move the cursor below the bin cal weight value
to the first digit of the measured cal weight and press the Enter key.
7. Press the INC or DEC keys to set the appropriate value for the selected digit
and press the Enter key to set the value.
8. Repeat the above procedure to set the remaining cal weight digits up to two
decimal places.
9. To program the cal weight value, press the Right key to move the cursor past
the last decimal place in the cal weight value and press the Send key. The
remote tank console will send the entered cal weight value to the appropriate
control node and display the bin calibration screen.
10.Press the Exit key to return to the bin selection screen.
The metering rollers will begin turning. Keep
away from moving components and alert
anyone around the air cart when performing the
catch test process.
WARNING
Product or Cal
Weight Value
12